41
2N TELEKOMUNIKACE a.s., www.2n.cz
®
Enter the command to set the count of counter pulses in case you do not want to
start from 0. In this case, 100 will be set. The available range is 0 –
4294967295.
at^scpulse1="stimer",60
Enter the command to define the intervals in seconds for storing the counter
value in the EEPROM. The available range is 5 – 10000s.
at^scpulse1="start"
Enter the command to enable pulse counting on input 1.
at^scpulse1="stop"
Enter the command to disable pulse counting on input 1
.
at^scpulse1="clear"
Enter the command to clear the input 1 counter.
at^scpulse1="save"
Enter the command to store the counter value in the EEPROM manually.
at^scpulse1?
Enter the command to display the current interface settings.
at^scpulse1=?
Enter the command to display the setting options for the interface.
at^scpulse2="state"
Enter the comma1nd to know the current states of the input 2 counter.
COUNTING- counting in progress
STOPPED- counting stopped
at^scpulse2="get_value"
Enter the command to read out the counter state.
at^scpulse2="set_value",100
Enter the command to set the count of counter pulses in case you do not want to
start from 0. In this case, 100 will be set. The available range is 0 –
4294967295.
at^scpulse2="stimer",60
Enter the command to define the intervals in seconds for storing the counter
value in the EEPROM. The available range is 5 – 10000s.
at^scpulse2="start"