Technical Parameters
6.1
90
6.1 Technical Parameters
Telephone Parameters
Parameter
Value
Conditions
Minimum line current
15 mA
off-hook
Minimum line voltage
22 V
on-hook
Off-hook DC voltage drop
< 8 V
< 16 V
I = 25 mA
I = 50 mA
Off-hook resistance
>1MΩ
U = 25..100
V
Off-hook impedance
220 Ω + 820
Ω paral. 115
nF
20 to 60 mA
Return loss
> 14 dB
20 to 60 mA
Bandwidth
300 to 3500
Hz
20 to 60 mA
Ringing impedance
> 2 kΩ
C = 1 μF
25 to 50 Hz
Ringing detector sensitivity
10 to 20 V
25 to 50 Hz
Pulse dialling
40 / 60 ms
DTMF dialling level
6 a 8 dB ± 2
dB
20 to 60 mA
Dial-tone detector sensitivity
approx. 43
dB
Overvoltage protection- between
A, B
1000 V
8 / 20 μs
Notes
All the product parameters comply with TBR-21 on condition that the
product is to be operated as a single line terminal, i.e. no parallel
connection with any other equipment is allowed.
Line interference and noise picked up by the LN microphone are relevant
factors.
Summary of Contents for LiftNet
Page 1: ...2N LiftNet Lift Communicator User Manual Version 1 9 3 Firmware version 1 9 1 www 2n cz ...
Page 3: ...2N LiftNet product is the holder of the Type certificate of the TÜV SÜD Czech company ...
Page 11: ...Product Description 1 1 11 Figure 1 3 Example of Fireman Connection in 2N LiftNet ...
Page 18: ......
Page 54: ......
Page 66: ......
Page 82: ......
Page 86: ...Battery Maintenance 5 1 86 ...
Page 88: ......
Page 92: ......