Lift Cabin Audio Unit
– Compact
2.3
40
Electric Installation (Earlier HW)
Caution
Be sure to connect the wires before wall mounting. The connectors are
separable – remove them, connect the wires, tighten the screws and
replace the connectors.
Connectors
Bus connector
CANCEL connector (optional)
in contact-control position
in voltage-control position
Electric Installation (Later HW)
Terminals
Telephone line / LN bus
Refer to ST or LN User Manual
ALARM
terminals
DC = voltage
control *)
5 – 24Vdc, any polarity
Emergency call
activation
N.O. = N/O contact Normally open contact
N.C. = N/C contact Normally closed contact
WARNING! If unused, the
contact should not be opened!
CANCEL
terminal
voltage control *)
5 – 24Vdc, any polarity **)
Emergency call
deactivation upon
door opening
contact control
any contact **)
*) For safety reasons, these terminals are electrically isolated from the telephone line.
**) You need not do anything to activate ALARM if you keep the factory settings. For
deactivation, voltage application or contact closing is necessary. To change the
settings use parameter 916 for ST and the rotary switch for LN.
Figure 2.12
Connectors of
Lift Cabin
Audio Unit –
Compact
(Earlier HW)
Summary of Contents for LiftNet
Page 1: ...2N LiftNet Lift Communicator User Manual Version 1 9 3 Firmware version 1 9 1 www 2n cz ...
Page 3: ...2N LiftNet product is the holder of the Type certificate of the TÜV SÜD Czech company ...
Page 11: ...Product Description 1 1 11 Figure 1 3 Example of Fireman Connection in 2N LiftNet ...
Page 18: ......
Page 54: ......
Page 66: ......
Page 82: ......
Page 86: ...Battery Maintenance 5 1 86 ...
Page 88: ......
Page 92: ......