Lift Cabin Audio Unit
– Universal
2.2
34
Indicator Connection
The basic configuration providing (using an external source) a sufficient illumination
intensity of indication elements is shown in the figure:
Requirements
The DC power supply has to be backed-up.
Notes
LN continues working except for the indicators during power outage.
The indication elements (bulbs, e.g.) may have the maximum current of
200 mA each.
Mind polarity in this case.
Alternative indicator connection (LED)
Today’s LED producing technologies help achieve a relatively good illumination
intensity at a low current supply. If a 5 mA LED (with diode loss of approx. 2V) is able
to provide efficient illumination in the lift, no power supply is needed. For this
configuration see
the figure below:
Notes
The cables required for this configuration are not part of the standard
delivery but are available upon agreement.
In this configuration, the auxiliary indicators on the PCB are not shining.
Figure 2.7
Basic
Indicator Connection for
Lift Cabin Audio Unit –
Universal
Figure 2.8
Alternative
Indicator Connection for Lift
Cabin Audio Unit – Universal