54
Table7-11
Parameter
Description
and
Configuration
Parameter
Parameter
Description
and
Configuration
F1/F2
F1/F2
indicates
the
IO
port
of
the
face
recognition
terminal.
Select
the
check
box
in
the
front.
Then,
the
configuration
of
the
IO
port
will
take
effect.
IO
ports
support
the
following
types
of
external
devices:
Door
lock:
The
face
recognition
terminal
outputs
door
opening
signals
to
door
locks
through
an
IO
port.
Pulse
Width
here
refers
to
one
door
opening
duration.
When
the
door
opening
duration
exceeds
this
time,
the
door
magnet
will
generate
an
alarm.
Value
range:
[1–300]s;
Default
value:
5s
Door
button:
The
face
recognition
terminal
can
receive
the
door
opening
signal
from
the
access
control
button
through
an
IO
port
and
sends
the
door
opening
signal
to
the
door
lock.
The
pulse
width
value
here
indicates
that
a
valid
door
opening
signal
is
generated
only
when
the
duration
in
which
the
door
opening
button
is
held
down
reaches
the
value
here.
Value
range:
[0–20000]ms;
Default
value:
100ms
Level
Value
can
be
set
to
Low
Level
or
High
Level
.
The
value
should
be
consistent
with
the
input
and
output
signal
level
supported
by
external
devices.
Unlock
Interval
It
indicates
the
interval
between
two
unlock
operations.
After
the
door
is
unlocked,
it
will
not
be
re
‐
unlocked
within
the
unlock
interval
even
if
a
new
unlock
signal
is
received.
In
addition,
the
door
opening
duration
of
the
door
lock
will
not
be
re
‐
timed.
If
it
is
set
to
0
,
door
unlock
will
be
triggered
each
time
the
unlock
signal
is
received,
and
the
door
opening
duration
of
the
door
lock
will
be
re
‐
timed.
Value
range:
[0–300]s;
Default
value:
0s
Door
Opening
Timeout
After
Auto
Door
Lock
Upon
Closing
is
enabled,
if
the
door
closing
time
exceeds
the
value
here
and
the
door
magnet
detects
that
the
door
is
in
the
closed
position,
the
face
recognition
terminal
automatically
locks
the
door.
Value
range:
[1–300]s;
Default
value:
10s
NOTE!
It
is
not
recommended
to
set
it
to
a
very
small
value.
Otherwise,
normal
door
opening
will
be
affected.
The
generation
of
a
door
magnet
alarm
is
related
to
door
opening
timeout.
Auto
Door
Lock
Upon
Closing
Select
whether
to
enable
auto
door
lock
upon
door
closing.
The
options
are
as
follows:
On:
When
the
door
magnet
detects
that
the
door
is
closed
and
the
door
closing
time
exceeds
the
value
of
Door
Opening
Timeout
,
the
door
will
be
locked
automatically.
Off:
The
auto
door
lock
upon
closing
is
disabled
and
the
door
closing
time
is
the
door
opening
duration
.
Check
Door
Magnet
Status
Before
Closing
The
options
are
as
follows:
On:
The
door
magnet
status
is
checked
before
closing.
Off:
The
door
magnet
status
is
not
checked
before
closing.
Door
Magnet
Check
Time
This
parameter
is
available
only
after
Check
Door
Magnet
Status
Before
Closing
is
set
to
On
.
Set
this
parameter
based
on
the
lock
type.
Before
Door
Closing:
Select
this
value
for
electronic
locks.
After
Door
Closing:
Select
this
value
for
electromagnetic
locks.
(3)
Click
Save
to
complete
the
IO
port
configuration.
(4)
Audio
If
the
face
recognition
terminal
connects
to
an
audio
device,
configure
audio
information
on
the
Audio
tab
page.
(1)
Choose
Setup
>
Common
>
Ports
&
Devices
and
click
the
Audio
tab.