65
NOTE!
You
can
set
this
parameter
only
when
Exposure
Mode
is
not
set
to
Shutter
Priority
and
when
Image
Stabilizer
is
disabled.
Slowest
Shutter
Set
the
slowest
shutter
speed
that
the
device
can
use
during
exposure.
NOTE!
You
can
set
this
parameter
only
when
Slow
Shutter
is
set
to
On
.
Compensation
Adjust
the
compensation
value
as
required
to
achieve
the
desired
effects.
NOTE!
You
can
set
this
parameter
only
when
Exposure
Mode
is
not
set
to
Manual
.
Metering
Control
Set
the
way
the
device
measures
the
intensity
of
light.
Center
‐
Weighted
Average
Metering:
The
device
measures
light
mainly
in
the
central
part
of
images.
Evaluative
Metering:
The
device
measures
light
in
the
customized
area
of
images.
Spot
Metering:
It
is
similar
to
Evaluative
Metering
but
the
difference
is
that
the
image
brightness
cannot
be
improved.
Face
Metering:
The
device
adjusts
the
image
quality
in
poor
lighting
conditions
by
controlling
the
brightness
of
captured
face
photos
in
Face
scene.
Interlligent
Metering:
In
case
of
poor
illumination
or
backlight
in
the
"face"
scene,
when
someone
passes
through
the
terminal
the
terminal
controls
the
brightness
of
the
captured
person
photo
or
face
photo
to
improve
the
snapshot
quality.
NOTE!
You
can
set
this
parameter
only
when
Exposure
Mode
is
not
set
to
Manual
.
The
default
value
is
Face
Metering
.
Face
Brightness
This
parameter
is
displayed
only
when
Metering
Control
is
set
to
Face
Metering
.
In
Face
Metering
mode,
the
system
adjusts
the
exposure
based
on
the
value
of
Face
Brightness
and
the
face
brightness
in
the
live
view
so
that
the
face
brightness
in
the
live
view
is
within
the
appropriate
range
(over
‐
exposure
or
under
‐
exposure
may
be
incurred
to
surroundings
on
the
images).
The
value
ranges
from
0
to
100
and
the
default
value
is
50.
A
larger
Face
Brightness
value
indicates
higher
image
brightness
on
the
device
and
brighter
face
snapshot
photos.
Min.
Duration(min)
This
parameter
is
displayed
only
when
Metering
Control
is
set
to
Face
Metering
.
It
refers
to
the
maximum
duration
that
the
screen
brightness
of
the
device
(applicable
to
the
previous
face)
can
be
retained
after
the
face
detection
of
the
previous
person
ends
and
the
face
of
the
next
person
is
not
detected.
The
timer
is
restarted
each
time
the
face
detection
of
a
person
ends.
After
the
time
expires,
the
device
adapts
to
the
average
brightness
of
the
current
environment
till
the
face
of
the
next
person
is
detected.
The
value
ranges
from
0
to
60
and
the
default
value
is
5.
Day/Night
Mode
Automatic:
The
device
outputs
the
optimum
images
according
to
the
light
condition.
In
this
mode,
the
device
can
switch
between
night
mode
and
day
mode
automatically.
Day:
The
device
provides
high
‐
quality
color
images
using
the
existing
light.
Night:
The
device
provides
high
‐
quality
black
and
white
images
using
the
existing
light.
Input
Boolean:
The
device
provides
high
‐
quality
images
by
using
external
light.
Day/Night
Sensitivity
Light
threshold
for
switching
between
day
mode
and
night
mode.
A
higher
sensitivity
means
that
The
device
is
more
sensitive
to
the
change
of
light
and
becomes
more
easily
to
switch
between
day
mode
and
night
mode.
NOTE!
You
can
set
this
parameter
only
when
Day/Night
Mode
is
set
to
Automatic
.
Day/Night
Switching(s)
Set
the
length
of
time
before
The
device
switches
between
day
mode
and
night
mode
after
the
conditions
for
switching
are
met.
NOTE!
You
can
set
this
parameter
only
when
Day/Night
Mode
is
set
to
Automatic
.