background image

Turnstile Controller User Manual

 | 2M Technology

2

www.2MTechnology.net

4. 

IR Number:

 number of IR sensors that are connected. The default number is 8.

5. 

Open Speed:

 speed of the gate opening. The default number is 5.

6. 

Open Angle:

 angle which the gate will open

7. 

IR Polarity:

 only for factory use

8. 

Test Mode:

 only for factory use

9. 

Open Direction:

 used to program the turnstile. Only for factory use

10. 

Safe Mode:

  a. Safe close: After people pass through, then the gate will close. This is the default setting and the most  
  suggested one to use.
  b. Safety zone
  c. Fast close: the gate will close faster (not suggested to use)
11. 

Open cnt:

 This is a memory function.

  a. Open count: If you tap a certain number of times continuously, then you will be able to pass that same  
  number of times. For example: if you tap your entry card 10 times continuously, the gate will grant 10 entries.
  b. Open one: will only let one person through, no matter how many times the card is tapped. For example: if  
  you tap your entry card 10 times continuously, the gate will still only grant 1 person through.
12. 

Count clr:

 clear the number of entries and exits

13. 

Link In:

 this function is used to integrate with fire alarms

14. 

Servo Type:

 only for factory use

15. 

Inner Swipe:

 allows for someone to be in the passageway and then tap their card instead of having to be outside 

of the passageway
16. 

LED Mode:

 to set the LED lights. Only applicable if we have sent you the appropriate LED lights.

17. 

Emergency Open:

 set the open direction when needing to open during an emergency (such as when the gate is 

powered off)
18. 

Reverse:

 means that when you tap your card at entry, one person will also be allowed to exit at the same time. 

Can have the gates close or maintain the same position
19. 

Tail In:

 when people follow in without tapping their own card, the turnstile should either close or maintain the 

same position

Summary of Contents for 2MGST-6

Page 1: ...2M TECHNOLOGY TURNSTYLE CONTROLLER User Manual REV04222021 ...

Page 2: ... Set 6 System Information Sys Info 1 Channel Parameters 1 In mode 3 entry options a Swipe uses the Input Output connections for card reader or facial recognition terminal b OffenOff locks the gate doors so they do not open c Free allows people to walk freely through the gates 2 Out mode 3 exit options a Swipe uses the Input Output connections for card reader or facial recognition terminal b OffenO...

Page 3: ...y the gate will grant 10 entries b Open one will only let one person through no matter how many times the card is tapped For example if you tap your entry card 10 times continuously the gate will still only grant 1 person through 12 Count clr clear the number of entries and exits 13 Link In this function is used to integrate with fire alarms 14 Servo Type only for factory use 15 Inner Swipe allows...

Page 4: ...er Mode 2 Set Zero setting the arm closing position 3 The rest of the settings in this section is only for factory use 3 Output Set 1 Pass out After people pass through the passageway then it will trigger the output 2 Alarm out disable or enable alarm signal output 3 Buzzer out disable or enable buzzer signal output 4 Alarm audio disable or enable an audio signal output ...

Page 5: ...xample if it is set to 5 seconds then the gate will close after 5 seconds after people pass through 4 IR Check Dly set the infrared sensitivity The smaller the value the more sensitive it will be Note please do not set this without one of our technician s assistance The default value has been set according to our recommendations 5 Alarm Dly Alarm time For example if it has been set to 5 seconds th...

Page 6: ...802 Greenview Dr Grand Prairie TX 75050 USA Toll Free 1 866 708 5401 Fax 1 972 999 4113 sales 2MTechnology net ...

Reviews: