![background image](http://html.mh-extra.com/html/2m-technology/2mgst-6/2mgst-6_user-manual_439719005.webp)
Turnstile Controller User Manual
| 2M Technology
4
www.2MTechnology.net
4. Audio Set
1.
Entry Prompt
– prompt when entering
2.
Exit Prompt
– prompt when exiting
3.
Break In
– prompt when there is unauthorized entry
4.
Tail Warn
– tailgating warning
5.
Stay Warn
– warning when a person is staying in the passageway for too long
5. Time Set
1.
Wait Time Out:
the amount of time that the gate will stay open after tapping your card. For example: The default
time is set to 5 seconds. If you tap your card, but no one goes through the passageway, after 5 seconds the gate will
close again.
2.
Stay Alarm Time:
if you stay in the passageway for the amount of time that is configured, then an alarm will sound.
3.
Off Time:
set the delay closing time. For example: if it is set to 5 seconds, then the gate will close after 5 seconds
after people pass through.
4.
IR Check Dly
: set the infrared sensitivity. The smaller the value, the more sensitive it will be. Note: please do not set
this without one of our technician’s assistance. The default value has been set according to our recommendations.
5.
Alarm Dly:
Alarm time. For example: if it has been set to 5 seconds, the alarm will sound for 5 seconds.
6. Sys Info
1.
Language
2.
Reset Para
– reset parameters
3.
Version
4.
Device Address
5.
RS232 Speed
– 115200, 38400, 19200, 9600, or 4800. The default is 115200. Only for factory use
6.
RS485 Speed
– 115200, 38400, 19200, 9600, or 4800. The default is 115200. Only for factory use
7.
Servo port
– RS232 or RS485. The default is RS232. Note: If this setting is changed, it can affect the operation of
the gate. Only for factory use
8.
Control PROT
– control protocol, RD001 or TB001. The default is RD001. Only for factory use