Turnstile Controller Manual Objectives: 

Controller screen counter, entering and exiting, and adjusting parameters in the menu

How to Enter the Menu:

 press “Confirm” and input the password

Password:

 “up”, “up”, “down”, “down”, “up”, “down”

Options in Menu:

 

1. Channel Parameters (Channel Para)

2. Factory Settings (Factory Set)

3. Output Settings (Output Set)

4. Audio Settings (Audio Set)

5. Time Settings (Time Set)

6. System Information (Sys Info)

1. Channel Parameters

1. 

In mode:

 3 entry options

  a. Swipe – uses the Input/Output connections (for card reader or facial recognition terminal)
  b. OffenOff – locks the gate doors so they do not open
  c. Free – allows people to walk freely through the gates
2. 

Out mode:

 3 exit options

  a. Swipe – uses the Input/Output connections (for card reader or facial recognition terminal)
  b. OffenOff – locks the gate doors so they do not open
  c. Free – allows people to walk freely through the gates
3.

 Gate type:

 choose gate option. This model is Servo Swing Gate type.

  a. Servo Swing Gate
  b. Tripod Gate
  c. Wing Gate
  d. Swing Gate
  e. Speed Gate

Preface

Summary of Contents for 2MGST-6

Page 1: ...2M TECHNOLOGY TURNSTYLE CONTROLLER User Manual REV04222021 ...

Page 2: ... Set 6 System Information Sys Info 1 Channel Parameters 1 In mode 3 entry options a Swipe uses the Input Output connections for card reader or facial recognition terminal b OffenOff locks the gate doors so they do not open c Free allows people to walk freely through the gates 2 Out mode 3 exit options a Swipe uses the Input Output connections for card reader or facial recognition terminal b OffenO...

Page 3: ...y the gate will grant 10 entries b Open one will only let one person through no matter how many times the card is tapped For example if you tap your entry card 10 times continuously the gate will still only grant 1 person through 12 Count clr clear the number of entries and exits 13 Link In this function is used to integrate with fire alarms 14 Servo Type only for factory use 15 Inner Swipe allows...

Page 4: ...er Mode 2 Set Zero setting the arm closing position 3 The rest of the settings in this section is only for factory use 3 Output Set 1 Pass out After people pass through the passageway then it will trigger the output 2 Alarm out disable or enable alarm signal output 3 Buzzer out disable or enable buzzer signal output 4 Alarm audio disable or enable an audio signal output ...

Page 5: ...xample if it is set to 5 seconds then the gate will close after 5 seconds after people pass through 4 IR Check Dly set the infrared sensitivity The smaller the value the more sensitive it will be Note please do not set this without one of our technician s assistance The default value has been set according to our recommendations 5 Alarm Dly Alarm time For example if it has been set to 5 seconds th...