Go!Control
Wireless
Security
System
|
Installation
and
Programming
Guide
46
Copyright
©
2014
Linear
LLC
Summary of Wired Sensor # Screen
After
setting
all
the
options
for
a
sensor,
the
wired
sensor
summary
screen
is
displayed.
The
screen
can
also
be
displayed
for
programmed
sensors
during
wired
sensor
program
editing
by
pressing
the
Sum
button.
•
While
programming
each
wired
sensor
remember
that
the
←
and
→
arrow
bu ons
step
through
each
of
the
wired
sensor
numbers.
•
To
return
to
programming,
click
the
Edit
Current
or
Edit
Next
buttons.
•
Pressing
Skip
goes
to
question
number
Q3
(RF
Key
Fob
Programming).
See
"Wireless
(RF)
Key
Fob
Programming"
on
page
48.
Figure 53
Summary of Wired Sensor # Screen
NOTE:
For
the
detailed
steps
of
programming
a
wired
sensor,
see
"Wired
Sensor
Programming
Questions"
on
page
46.
Wired Sensor Programming Questions
Q2: Select Wired Sensor # (1-2)
Two
hardwire
loops
can
be
used
as
sensors
with
each
Control
Panel.
The
options
for
each
wired
sensor
are
programmed
with
sub
‐
option
questions.
•
Begin
by
entering
the
wired
sensor
number
or
select
it
using
the
←
or
→
arrows.
•
After
selecting
the
wired
sensor
number,
program
the
wired
sensor
details
by
using
the
↑
and
↓
arrows
to
select
each
of
the
sub
‐
options.
NOTE:
To
skip
wired
sensor
programming,
press
Skip
to
jump
from
question
Q2
to
question
Q3.
See
"Wireless
(RF)
Key
Fob
Programming"
on
page
48.
Q: Select Wired Sensor# Type
DEFAULT:
(00)
Unused
Each
wired
sensor
needs
to
be
assigned
to
a
sensor
type.
Select
the
sensor
type
that
matches
the
wired
sensor’s
func on
using
the
←
or
→
arrows
or
enter
the
sensor
type
number
directly
on
the
keypad.
In
the
table
below,
a
“YES”
indicates
the
sensor
type
can
be
used
for
the
wired
sensor.
An
“NO”
indicates
the
sensor
type
is
not
used.
Q: Select Wired Sensor# Equipment Type
DEFAULT:
Varies
by
wired
sensor
type
This
question
is
only
displayed
when
certain
sensor
types
are
selected.
The
equipment
type
selection
will
affect
the
sensor’s
extended
reporting
code.
The
following
sensor
types
require
equipment
type
selection:
•
Select
the
equipment
type
that
matches
the
sensor
equipment
using
the
←
or
→
arrows,
or
enter
the
equipment
type
number
directly
on
the
keypad.
NOTE:
This
Control
Panel
does
not
provide
auxiliary
accessory
output
power.
Connecting
a
hardwire
PIR
using
equipment
type
“motion”
will
require
an
external
stand
‐
alone
battery
backed
‐
up
power
supply
for
the
PIR.
Q: Select Wired Sensor# Equipment Code (0-9999)
DEFAULT:
(0)
Select
the
four
(4)
‐
digit
equipment
code
that
corresponds
to
the
appropriate
sensor
model.
See
"Equipment
Codes"
on
page
40.
Q: Select Wired Sensor# Equipment Age (0 to 1)
DEFAULT:
(0)
New
The
Control
Panel
can
be
used
with
new
or
existing
wired
sensors.
•
If
this
wired
sensor
is
new
for
the
installation,
leave
the
default
setting
of
(0)
New
.
•
If
this
wired
sensor
is
already
installed,
select
(1)
Existing
.
Sensor
Types
(Zones)
RF
Sensors
Wired
Sensors
(00)
Unused
Yes
Yes
(01)
Exit/Entry
1
Yes
Yes
(02)
Exit/Entry
2
Yes
Yes
(03)
Perimeter
Yes
Yes
(04)
Interior
Follower
Yes
Yes
(05)
Day
Zone
Yes
Yes
(06)
24
‐
Hour
Silent
Alarm
Yes
Yes
(07)
24
‐
Hour
Audible
Alarm
Yes
Yes
(08)
24
‐
Hour
Auxiliary
Alarm
Yes
Yes
(09)
24
‐
Hour
Fire
Yes
No
(10)
Interior
with
Delay
Yes
Yes
(14)
24
‐
Hour
Carbon
Monoxide
Yes
No
Sensor
Type
Equipment
Types
Available
(04)
Interior
Follower
(1)=motion
(2)=contact
(06)
24
‐
Hour
Silent
Alarm
(1)=contact
(11)=emergency
(07)
24
‐
Hour
Audible
Alarm
(1)=contact(
11)=emergency
(08)
24
‐
Hour
Auxiliary
(1)=contact
(6)=freeze
(8)=water
(10)=termperature
(11)=emergency
(10)
Interior
with
Delay
(1)=motion
(2)=contact
(23)
No
Response
Type
(1)=contact
(2)=motion
Sensor
Types
(Zones)
RF
Sensors
Wired
Sensors