Chapter 5 Initial Setup Example
XGS1930 Series User’s Guide
65
2
In the
Static VLAN
screen, select
ACTIVE
, enter a descriptive name in the
Name
field and enter 2 in the
VLAN Group ID
field for the
VLAN2
network. Use the default VLAN type, Normal, in the VLAN Type field.
Note: The
VLAN Group ID
field in this screen and the
VID
field in the
IP Setup
screen refer to the
same VLAN ID.
3
Since the
VLAN2
network is connected to port 1 on the Switch, select
Fixed
to configure port 1 to be a
permanent member of the VLAN only.
4
To ensure that VLAN-unaware devices (such as computers and hubs) can receive frames properly, clear
the
TX Tagging
check box to set the Switch to remove VLAN tags before sending.
5
Click
Add
to save the settings to the run-time memory. Settings in the run-time memory are lost when the
Switch’s power is turned off.