background image

FV741 Rev.  A 01/20/21

Page 4

    

FV741 Rev.  A 01/20/21

Page 3

   

 

4.  Assemble the electronics module

Do not connect the electronic module to spout

Cable to 

monitor

1.  Install Monitor on wall surface within 2 feet radius of faucet  

with dry wall anchors & screws or doubled sided VHB tape

2.  Loosen lid screw with supplied 3mm Allen wrench. Open lid 

and install supplied batteries. Close lid and tighten lid screw.

5.  Tighten electronics module assembly to shank and connect 

water line(s).

3. 

Connect monitor and electronics module assembly.

Do not connect cable to the spout at this step.  

4.  Open battery module using supplied 3mm Allen wrench and 

install supplied batteries in the electronics module.  Then close 

and tighten battery module..   

Use AA Lithium Batteries or AA Alkaline batteries, but do not mix Lithium 

with Alkaline.  

Use AA Lithium Batteries or AA Alkaline batteries, but do not mix Lithium 

with Alkaline.  

Monitor & Electronic Module Installation Instructions

2.  Install spout to sink using spout base gasket, plastic mounting 

washer, star washer and mounting nut.
Note: Faucet location needs to be within 3 feet radius above 

electrical outlet for ACA configurations.

NOTE

: Before installation, turn off water supplies to existing faucet and remove faucet if replacing an existing device. 

Clean the faucet basin and clear away debris. Flush all supply lines before connecting the faucet. Failure to do so 

may result in debris clogging the inlets and/or internal control and mixing valve

1.  Carefully screw aerator into spout using included tool.  

      Take care to not pinch blue o-ring

3.  Ensure that slot in plastic washer is facing forward.  

Sensor cable should not pass through plastic mounting washer.

Spout Installation Instructions

Z6913-XL-W2  

Z6915-XL-W2

Cover Plate Installation Instructions

1.  (For faucets with -CP4 or -CP8 suffix).  

Remove adhesive backing from gasket and then pass sensor 

connector wire and shank through gasket.  Align gasket with 

faucet bottom and press firmly together.  Pass sensor connector 

and shank through cover plate and fasten to the faucet with the 

provided screws.

      

Содержание AquaSense Z6913-XL-W2

Страница 1: ... of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective g...

Страница 2: ...nstructions should be left on site with the facility or maintenance manager Specifications Voltage 6 VDC Series 4 AA Alkaline or Lithium for faucet 4 VDC Series 4 AA Alkaline or Lithium for monitor Sensor Range Self calibrated dependent upon sink depth and finish Operating Water Pressure 10 125 psi Operational Water Temperature 33 F to 140 F 1 C to 60 C Aerator 1 5 GPM Vandal Resistant Standard Im...

Страница 3: ... Instructions 2 Install spout to sink using spout base gasket plastic mounting washer star washer and mounting nut Note Faucet location needs to be within 3 feet radius above electrical outlet for ACA configurations NOTE Before installation turn off water supplies to existing faucet and remove faucet if replacing an existing device Clean the faucet basin and clear away debris Flush all supply line...

Страница 4: ...eway is now ready to transmit data from your Zurn connected product 4 Zurn Gateways have been set to DHCP by default Please consult local IT support for possible additional access requirements for your network Step 3 Determining general Location for the Zurn Gateway Select a location central to all devices to be connected to this gateway Place the gateway as high as possible such as near the top o...

Страница 5: ...Off Off Off Off Off Off On On Mode Select Sensing Mode Metering Mode Off On Sensor Sensitivity Low Off Normal On Mode A Off Mode B On Adjustable modes and features selection For further assistance with troubleshooting visit http www zurn com Problem Possible Cause Corrective Action Faucet is non responsive Battery voltage low or no power Change out batteries or verify power provided by ACA Sensor ...

Страница 6: ...4 29 PM CDT If listed as Deactivated contact Zurn Customer Service at 1 855 ONE ZURN 1 855 663 9876 for assistance Step 3 If problem still present the LoRa Monitor electronics may be faulty Contact Zurn Customer Service at 1 855 ONE ZURN 1 855 663 9876 for assistance with additional troubleshooting steps and if needed unit replacement Problem Corrective Action Status Good posted in plumbSMART and ...

Страница 7: ...g maintenance to verify sufficient water pressure in lines Step 4 If problem persists the LoRa Monitor may be paired to the incorrect fixture model Verify product image and model number from plumbSMART product page Details tab against model number cited on product literature and packaging If incorrect contact Zurn Custom Service at 1 855 ONE ZURN 1 855 663 9876 for assistance High Daily Faucet Act...

Страница 8: ... 4 5 Z6913 XL W2 Z6915 XL W2 Parts List Description Product No Z6915 Spout Assembly with Sensor Item 1A P6915 XL 2 Z6913 Spout Assembly with Sensor Item 1B P6913 XL 2 Z6915 Base Plate Gasket Item 2A P6915 42 WEDGE Z6913 Base Plate Gasket Item 2B P6913 42 WEDGE Mounting Kit Item 3 P6900 43 Electronics Box with Solenoid Item 4 P6950 XL B L Smart Connected Faucet Retrofit Kit Item 5 P6900 RK W2 4 Cas...

Страница 9: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev A Date 01 20 21 C N No 143366 Prod Dwg No FV741 ...

Отзывы: