background image

ZDAS-16CA SERIES PROGRAMMING GUIDE 

 

--------------------------------------------------------------------------------------------------------------------------------------------------------

PAGE 

13

  OF  19 

 

“Dis-Arm” status once the Access Zone is triggered; system will restore “ARM 
“ status if it’s no trigger of this special zone); Factory setting is “0” 

(Note: “1”, “2”, “4” , “6” zone type is 24-hour ARM status, not effected by ARM or DIS-ARM 
operation. 

 

Siren status: 0 alarm without sound; 1 sound alarm, factory setting is “1” 

4.9 Set Boundary(Home) Arm

Only for ZDAS-16CA-8/16CA-16/16CA/8CA

 

Format: 19 + Zone number (2 bit) + 0/1(0 close, 1 open)+ 

    (Zone number: 01~16) 

4.10 Doorbell function setting

Only for ZDAS-16CA-8/16CA-16/16CA/8CA

 

Format: 60 + Zone Number (1 bit) + 0/1 + 

  (confirm key)     

zone number:1~8

 

  “1”  open,  “0”  close  Factory  setting  is  “0”),  when  zone  set  as  Door-Bell  zone,  it  will  be  Doorbell 
function in DIS-ARM status, zone will restore normal in ARM status. 

Note: The 8th Zone is defined as fixed doorbell zone. The 8th zone will not be affected by set 

Arm or Dis-Arm if it’s set as doorbell zone. 

4.11 Set User Code (Alarm Center Code) 

Format: 31

4 bit User code

  (Confirm Key); 

Delete User Code: 32

  (Confirm Key)

 

4 bit user code is allocated the entering code for alarm center. 

Note: Don’t use this operation if not connect with alarm center. 

4.12 Set ARM Delay(Exit Delay) Time

 

  

 

   

Format: 40

Time(3 bit)

  (Confirm Key) 

     

Time: 000

255 seconds 

4.13 Set Alarm Delay(Entry Delay) Time

 

  

 

   

Format: 43

Time(3 bit)

  (Confirm Key) 

     

Time: 000

255 seconds 

4.14 Set Telephone Number 

1. Set Central alarm telephone number   

Format: 50

Telephone Number

  (Confirm Key)

 

(Don’t use this operation if not connect 

with alarm center.) 

Delete center telephone number: 50

  (Confirm Key) 

2

Set User alarm telephone number 

Format: 5+ group of phone number (1bit)+phone  

  (Confirm Key) 

Group of phone number: 1-6        means: 1

st

 to 6

th

 group telephone number. 

3.    Delete User alarm telephone number 

Format: 5+ group of phone number (1bit) 

+

 

  (Confirm Key) 

4

 Set telephone number for connecting internal line to external line 

Format:  5+  group  of  telephone  number  (1bit)  +  Preset  number  in  Program  control  exchange 
machine  (the  preset  number  is  the  additional  dialing  number  such  as  0  or  9  etc  before  you  dial 
external line from internal line) + 

  + phone  

(Confirm Key) 

Group of telephone number: 1~6    means: 1

st

 to 6

th

 group telephone number 

Note: The system will auto-dial preset telephone number cycled for 10 times until confirmed when 
accident  happen.  Alarm  center  phone  number  will not  be  stopped  dialing  after  Dis-Arm,  but  user 
alarm number will stop dialing immediately after Dis-Arm. 

4.15 Set 7 Groups Telephone Format 

Format: 77 + group of telephone number (0-6) + Format (1 bit) 

  (group 0~6 correspond 50-56) 

Format:    “0”  “1”  is  center  communication  protocol  (“0”  CID,  “1”  program  4+2),  “5”  user’s 

telephone, ”6

 ARM 

telephone,”7

 Dis-Arm 

telephone, “8” Regular checking

 

Format after reset: “0” is 0, “1--6” group is 5 

Содержание ZDAS-16CA

Страница 1: ... PAGE 0 OF 19 SYSTEM ZDAS 16CA SERIES PROGRAMMING GUIDE USER MANUAL ZDAS 16CA SERIES Ver 1210 2010 12 27 ...

Страница 2: ...black negative line with negative terminal The incorrect connection will cause damage of main panel σ Rechargeable current 1 5A σ Avoid metal parts or hand contact to the electronic parts on the circuit when install the lines σ Must use 2 7K resistor short unused wired zone σ Mark wires to avoid miss connection when using too many wired zones σ Cut off all AC power supply battery and telephone lin...

Страница 3: ...odule 10 20seconds record voice alarm function σ Set the alarm delay time and siren yelp time σ Search record of emergency σ Remote controller can be used to set alarm DIS Arm emergency alarm and other operation only for ZDAS 16CA 8 16 16G σ Operate from keypad easily and convenient σ Phone line malfunction indication function system will alarm when phone line is cut off or short σ The alarm diall...

Страница 4: ...AGE 3 OF 19 Chapter 2 Installation and Connection 2 1 Wiring Diagram 2 1 1 Wiring diagram on main board indicator LED will light on when working normally Z1 Z8 means 1 8 zone 2 1 2 Wiring diagram of expand board only for ZDAS 16CA 16CA 16 ...

Страница 5: ...ors connecting is the same with Z1 Z8 Set expanded 9 16 wired zones ON OFF 1 Insert the expand module Factory setting inserted 2 Start setting mode see 4 3 3 Format 79 status Confirm key Status 0 9 16 zones OFF 1 9 16 zones ON Factory setting 0 4 Exit see 4 4 Note The RESET can not return to factory default setting it must be manual setting 2 1 4 8 way output module Optional ...

Страница 6: ...stor to the signal terminal of wired detector One of the signal connector should be soldered to the resistor The other end of resistor should be connected to the other signal terminal of detector by corresponding signal wire and then connected to GND port of main board 2 NORMALLY OPENED Connecting a 2 7K resistor in parallel connection to the terminal detector of the loop of each zone 2 3 2 Connec...

Страница 7: ...connected in series to avoid destroy of keypad the anti temper port could be connected to the terminal of alarm panel 2 7 3 Keypad address no address jumper means NO 1 keypad insert address jumper 1 means NO 2 keypad insert address jumper 2 means NO 3 keypad insert address jumper 1 2 means NO 4 keypad 2 7 4 Close the cover when the connection is finished 2 8 Installation when wireless zones only o...

Страница 8: ...m message to control center by telephone network if set to send the alarm to control center 3 1 3 If telephone number is set it will dial the preset numbers in turn After connecting telephone it can remote control see 3 7 by telephone 3 1 4 Zone LED will keep light on in alarm status untill alarm memory is erased 3 2 Operation of Remote Controller only for ZDAS 16CA 8 16 16G Remote Controller ARM ...

Страница 9: ...dicate the Zone disarm after Alarm but the alarm status hasn t been erased Slow Flashing Wired Zone bad connection the Circuit is Open or Short Lighting in 1 Second Zones in Effect on ARM Status Emergency Key 24 hours Alarm Status can be defined as Fire Alarm Robbery Alarm Emergency Call No indicator no sound while alarm If telephone preset it will dial the number while alarm the communication lig...

Страница 10: ...ntroller to set Boundary ARM Boundary Arm see 4 9 3 4 3 Set Single Zone ARM DIS ARM the specified zone start ARM status the other zones will not activated alarm Operation Set single zone ARM Zone Number 01 16 Shortcut Key Set single zone DIS ARM Password 6 bit Zone Number 01 16 Shortcut Key 3 4 4 Set Fast ARM system will ignore the Delay Arm status to ARM the system directly Operating press 3 4 5 ...

Страница 11: ... start ARM press 2 to Disarm stop dial the next phone number after ARM started press 3 to start Remote Monitor press 8 to Return end monitor press 7 change recorded voice message press 6 play the recorded voice and confirm press 8 Exit recording voice press 4 Start siren press 5 Close siren and return to remote control status Note the meaning of 1 2 3 in Remote control status and Pick up phone ope...

Страница 12: ...ry Name Factory Settings 1 Installer Password 666666 2 User Password 123456 3 Zone Type 0 Instant alarm zone 4 Play recorded voice automatically 0 Inefficacy 5 AC Power Failure check 0 no checking 6 Keypad line cut off check 0 no checking 7 Keypad anti disassembly check 0 no checking 8 Telephone Remote Control 0 Inefficacy 9 Ring Times 8 times 10 Delay ARM 0 no delay time 11 Telephone Line Check N...

Страница 13: ...nds Status If Exit set status successfully the buzzer will sound a long Di the indicator LED will light off Or exit automatically after 30 seconds the buzzer will not sound indicator LED off Note All operations for the following step 4 5 4 39 must be carried out under Set Mode status please exit set mode if need normal operation 4 5 Change Installer Password Format 30 New Installer Password 6 bit ...

Страница 14: ...ay Entry Delay Time Format 43 Time 3 bit Confirm Key Time 000 255 seconds 4 14 Set Telephone Number 1 Set Central alarm telephone number Format 50 Telephone Number Confirm Key Don t use this operation if not connect with alarm center Delete center telephone number 50 Confirm Key 2 Set User alarm telephone number Format 5 group of phone number 1bit phone number Confirm Key Group of phone number 1 6...

Страница 15: ...omatically play voice message within 5 seconds after picking up phone or press 1 to play voice message 4 22 Open Close Telephone Line Checking Format 78 Status 1 bit Confirm Key Status 0 No Checking 1 Checking Alarm while line is cut Factory Setting 0 No Checking 4 23 Set Programmable 4 2 Code for different Alarm Center Format 8 zone number 01 16 set alarm code 2 bit Set alarm code for zone 1 8 8 ...

Страница 16: ... 4 30 Checking Time Setting Format 25 AC power checking time 1 bit Battery voltage checking time 1 bit Telephone line checking time 1 bit Time 0 1S 1 2S 2 5S 3 10S 4 30S 5 180 Seconds Factory setting AC power checking time 3 Battery voltage checking time 3 Telephone line checking time 0 4 31 Zone Sensitivity Setting Format 26 Zone Number 2 bit Sensitivity 1 bit Zone number 01 16 Sensitivity 0 40 M...

Страница 17: ... output 2 close output For example under remote control status 1 1 means open output of the 1st way 1 0 means close output of the 1st line 4 40 View The Recording Event Log Operating 99 2 Enter viewing events status Record method number days things hour minute Events 01 16 is zone alarm 30 is Arming 40 is Disarming press to view the next event under viewing events status 4 41 PROG GSM function onl...

Страница 18: ...rd 6 bit 1 for arming User password 6 bit 2 for disarming Note Above operation must be under remote control statis 711 F4 See 4 18 in page 18 of manual ZDAS 16CA 8 7 How to Program the SMS for every zone every event by users Program and send following SMS to the SIM card of GSM panel if the SMS setting is successfully the panel will give a short sound di and store these messages automatically then...

Страница 19: ...ZDAS 16CA SERIES PROGRAMMING GUIDE PAGE 18 OF 19 Note when zone set as Door Bell zone it will be Doorbell function in DIS ARM status zone will restore normal in ARM status ...

Отзывы: