• Use the VARIO BALANCE for its designated purpose only.

• Use the VARIO BALANCE indoors only.

• Do not deploy the VARIO BALANCE in the immediate vicinity of heat sources such as

Bunsen burners, heating ovens etc.

• Do not immerse the VARIO BALANCE in water or any other liquid.

• Place the VARIO BALANCE scales on a stable and level surface.

• Do not overload the VARIO BALANCE. Read and comply with the Technical Speci-

fications. Load the VARIO BALANCE only for the purpose of weighing or metering.

• Do not place the VARIO BALANCE near devices that emit electromagnetic radiation

such as mobile phones or radio devices, as this may lead to incorrect readings or
device malfunction.

• The bottom of the VARIO BALANCE is equipped with feet. As furniture and floor

surfaces may be cleaned or treated with a variety of cleaning products, the possibility
cannot be completely ruled out that these may contain chemical substances that react
chemically with the material in the standing feet.

• Do not place the VARIO BALANCE where children have unsupervised access to it. Keep

packaging material away from children – may cause suffocation when swallowed.
Make sure that the packaging bag is not fitted over anybody’s head.

• Retain the original VARIO BALANCE packaging material. Use the original material when

transporting the unit. Transporting the unit in an inappropriate way will invalidate the
warranty.

• In the event of defects or damage that preclude safe operation of the VARIO BALANCE,

secure the device against inadvertent use.

• Unplug the AC adapter of the VARIO BALANCE prior to performing recommended and

authorized maintenance or service to avoid the risk of electric shock, injury or death.

• Do not attempt to open, repair or replace a part of the VARIO BALANCE. Any unautho-

rized attempt to open or repair the device or to replace parts may constitute a safety
risk and may invalidate the warranty.

• When servicing the VARIO BALANCE, use original replacement parts only.

• Cleaning: Always disconnect the power cord before cleaning the VARIO BALANCE.

Clean by wiping down with a dry or lightly moistened cloth only. Do not use solvents.

Safety instructions

Page

Zubler Gerätebau GmbH

D-89 081 Ulm

Tel. +49(0)731-14 52-0

Содержание VARIO BALANCE

Страница 1: ...1 Seite www zubler de VARIO BALANCE Operating instructions 09 2011 en Dosage Device...

Страница 2: ...e VARIO BALANCE 2 2 Normal weighing 2 3 Programming 2 3 1 Add Change material 2 3 2 Copy Change material 2 3 3 Move a material 2 3 4 Erase a material 2 4 Set up menu 3 Malfunction Seite 14 4 Safety in...

Страница 3: ...omer Thank you for purchasing a Zubler metering balance We hope this system will give you a pleasant workplace experience Our technology undergoes continuous improvement and development based on our c...

Страница 4: ...ding on context 1 Red key Cancel or return to initial setting 2 Green key Confirm or proceed to next step 3 Yellow key up down Move cursor upward downward Increment decrement value Select letters digi...

Страница 5: ...Unpack the scales and its AC adapter In case of visible damage please contact your supplier immediately Place the scales on a stable and level surface Connect the AC adapter to the AC connector on th...

Страница 6: ...ezialkonz Measured liquid 19 8ml Measure powder 99 2g Move the cursor with the yellow key up down to the desired concentration Confirm by pressing the green key If you selected Special dilute Confirm...

Страница 7: ...green key Add the required amount of investment or stone gypsum Both a numeric value and a progress bar will guide you through the process until the desired amount of powder is reached The first valu...

Страница 8: ...key up down to Add Change material Confirm by pressing the green key Add Change Copy Change Move a material Erase a material 0 0g Move the cursor with the yellow key up down to the desired program lo...

Страница 9: ...m the dilute Confirm by pressing the green key 5 For the two remaining pre programmed dilutes proceed as shown under 1 to 4 above Use the yellow key up down to select the desired letter digit or speci...

Страница 10: ...ge material Confirm by pressing the green key Move the cursor with the yellow key up down to the desired program location Use the yellow key up down key to jump five program locations forward or back...

Страница 11: ...or special character for the first of three pre programmed dilutes 2 Use the yellow key left right to move to the next or previous character 3 Once you have entered the name Confirm by pressing the gr...

Страница 12: ...a material Confirm by pressing the green key Move the cursor with the yellow key up down to the desired program location Use the yellow key up down to jump five program locations forward or back at a...

Страница 13: ...wn to Erase a material Confirm by pressing the green key Move the cursor with the yellow key up down to the desired program location Use the yellow key up down to jump five program locations forward o...

Страница 14: ...ice that may cause electromagnetic interference Remove all materials from the scales and reset it to zero by selecting Tare scale Has the scales been overloaded 2 4 Set up menu Tara scale Run batch pr...

Страница 15: ...BALANCE where children have unsupervised access to it Keep packaging material away from children may cause suffocation when swallowed Make sure that the packaging bag is not fitted over anybody s head...

Страница 16: ...hanges without notice en Order No Scales 898 420 AC adapter Input AC100 240V 50 60Hz Output DC9V 800mA 208 020 Length 215mm Width 170mm Height 75mm Weight 1 1kg Voltage Input 100 240V 50 60Hz 0 3A Max...

Отзывы: