Start temperature
The temperature in the firing chamber at which the program begins.
Pre dry
Selecting "
YES
" activates the pre-drying program.
Pre dry time
Enter a time value. In this section, the lift looks for a predetermined position over the entire
period, depending on the radiated heat of the heating chamber, in which the object is thus
pre-dried at a constant temperature.
Closing time
Specifies the time from the open to the fully closed lift
Soak temperature
At this temperature, the firing object remains in the closed firing chamber to warm it up to the
starting temperature. This serves to evenly "burn through" a ceramic work. Soak temperature
= Vacuum start.
Soak time
Indicates the dwell time of the object in the heating chamber before the temperature rises
and before the vacuum pump is switched on.
Heat rate
Respective temperature increase in °C °F/min to reach the final temperature.
Heat rate 1-2
Respective temperature increase in °C °F/min to reach the final temperature.
Final temperature
The temperature at which the ceramic is fired.
Final temperature 1-2
The respective final temperature at which the ceramic is fired.
Hold time
Residence time of the ceramic at the final temperature.
Hold time 1-2
Dwell time of the ceramic at the final temperature.
Temper
The tempering program is activated by selecting "
Yes
".
Temper temperature
The ceramic is tempered at this temperature, i.e. thermally treated with pinpoint accuracy at
a constant temperature.
Temper time
Indicates the duration of the thermal treatment with the heating chamber closed.
TTC
Activates linear cooling to the desired temperature using temperature gradients
TTC Cool rate
Cooling in °C °F/min to reach the opening temperature. Recommendation: heating rate =
cooling rate
Opening temperature
Indicates the temperature at which the oven opens. When using TTC, the opening
temperature must be below the end temperature. The linear cooling in TTC mode takes
place until this temperature is reached. Recommendation: opening temperature = starting
temperature or Tg of the ceramic used.
Opening time
The time it takes for the lift to fully open.
Vacuum
Activation or deactivation of the vacuum function (is a 2nd holding time at a lower
temperature in relation to the final temperature) it determines the time at which the firing
chamber is ventilated.
Release vacuum
Limits the time to vent the heating chamber. You can choose from:
During the heat up phase:
Release vacuum: Heat up
During the hold time at final temperature;
Release vacuum: Hold time
During the cool down period;
Release vacuum: Cooling
Vacuum end
Defines exactly when the heating chamber is ventilated. A time or temperature value must be
entered here, depending on which phase vacuum was selected.
Save
Save the program
2.1.8 Explanation of terms