![Zte ZXSDR BS8908 G060 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/zte/zxsdr-bs8908-g060/zxsdr-bs8908-g060_user-manual_940278021.webp)
Chapter 3 System Structure and Principles
Table 3-2 Indicators and Buttons
Color
Name
Meaning
Work Mode
Flashing at 1 Hz: Normal status
Flashing at 5 Hz: Loading program
Green
RUN
Power supply and board
running indicator
OFF: No power supply or power supply alarm
Constantly ON: Normal status
Flashing at 1 Hz: USB connection is normal
Flashing at 5 Hz: USB command is being executed
Green
ABIS
ABIS FE and optical inter-
face indicator; USB con-
nection indicator
OFF: the optical/electrical interface is abnormal
Constantly ON: the primary cabinet is normal
Green (flashing): the secondary cabinet is normal
Green
LC
Side-by-side cabinet in-
terface indicator
OFF: abnormal
Flashing: GPS is being initialized
Constantly ON: indicating fault
Red
REF
GPS indicator
OFF: normal
ON: there is power output
Green
PA
Power indicator
OFF: there is no power output
Constantly ON: VSWR alarm
Red
VSWR
Antenna feeder interface
indicator
OFF: normal
Flashing at 8 Hz in the first second and flashing
once: the 0th E1 is normal; OFF: the 0th E1 is
unavailable
Flashing at 8 Hz in the third second and flashing
twice: the 1st E1 is normal; OFF: the 1st E1 is
unavailable
Flashing at 8 Hz in the fifth second and flashing
three times: the 2nd E1 is normal; OFF: the 2nd
E1 is unavailable
Green
TDM
E1 interface indicator
Flashing at 8 Hz in the seventh second and
flashing four times: the 3rd E1 is normal; OFF: the
3rd E1 is unavailable
OFF: normal
Red
ALM
Alarm indicator
ON: alarm
3-3
SJ-20101104174421-001|20110425(R1.1)
ZTE Proprietary and Confidential
Содержание ZXSDR BS8908 G060
Страница 5: ...Glossary V III ...
Страница 6: ...IV ...