Chapter 5 ZXR10 2800-3E Chassis
5.2 Power Supplies
ZXR10 ZSR V2 serial routers support a voltage within the range of 100 V–240 V, AC power
of 50 Hz –60 Hz, and DC power from -38 V to -72 V. The 1+1 dual-power redundancy mode
and power supply swapping are available.
The power modules have the following functions:
l
Alarms are generated due to a high input or output voltage.
l
Alarms are generated due to a high output current.
l
Alarms are generated due to a high or low temperature.
Caution!
Turn off both power supplies before installing and maintaining the ZXR10 ZSR V2.
5.2.1 AC Power Module
Panel
shows the panel of the AC power module of a ZXR10 2800-3E chassis.
Figure 5-5 Panel of the AC Power Module
Indicators
For functions of the indicators on the AC power module of the ZXR10 2800-3E chassis,
refer to
Table 5-4 Functions of the Indicators on the Panel of the AC Power Module of the
ZXR10 2800-3E Chassis
Indicator
Number
Color
Description
RUN
1
Green
The power module is operating properly.
ALM
1
Red
The power module is operating improperly.
Buttons
For functions of the power buttons on the AC power module of the ZXR10 2800-3E chassis,
refer to
5-5
SJ-20150204153047-004|2015-03-30 (R1.0)
ZTE Proprietary and Confidential