ZXMW NR8120A/8120D Maintenance Guide
Parameter
Description
Interval
Sets the interval between sending functional packets. If
Operator
Type
is set to
Test Transmission
or
Test Reception
, this parameter
becomes unavailable.
Transmit Type
Sets the packet transmit type to be
Unicast
or
Multicast
.
Performance Test
Sets whether the function is enabled.
RMEP ID
Sets the remote MEP ID.
Require Times
Sets the number of times that a functional packet is transmitted. If
Operator Type
is set to
Test Transmission
or
Test Reception
, this
parameter becomes unavailable.
TST Transmit Rate
Sets the packet transmitting rate. This parameter is valid only when
the
Operator Type
parameter is set to
Test Transmission
or
Test
Reception
.
TST Packet Length
Sets the packet length. This parameter is valid only when the
Operator
Type
parameter is set to
Test Transmission
or
Test Reception
.
TST Test Time
Sets the test duration. This parameter is valid only when the
Operator
Type
parameter is set to
Test Transmission
or
Test Reception
.
3.
In the left navigation tree, select
ETH > OAM_CFM > Loopback
. The
CFM Loopback
pane is displayed on the right.
4.
Set the parameters, and click the
Apply
button.
The CFM loopback function is
enabled, see
Figure 3-5 CFM Loopback Pane
For a description of the parameters, refer to the following table.
3-6
SJ-20150804150350-006|2015-09-17 (R1.0)
ZTE Proprietary and Confidential