background image

 FEATURES:

 SAFETY INSTRUCTIONS:

 DRIP LOOP:

ENGLISH: AQUARIUM 

COOLING FAN.

 

INSTRUCTIONS: 

ITEM# AA-13E

Congratulations on purchasing Zoo Med’s 
new AQUACOOL Aquarium Cooling Fan! This 
compact fan will help to prevent overheating 
in your aquarium by directing airflow over the 
water or up at the aquarium lighting. Please 
read and follow these instructions carefully 
before using your new fan. If you have any 
questions regarding these instructions or the 
proper use of this product, please contact our 
customer service department at the phone 
or email address listed below. Thank you for 
purchasing a quality Zoo Med product!

• Low voltage (12V) for maximum safety 

when used near a wet environment.

• Better than overhead fans: Side-mounted 

fan assembly to minimize water splash 

on the motor and to prevent accidental 

immersion.

• Multi-directional discharge nozzle for 

precise air flow focus.

• Fully adjustable, wide discharge nozzle for 

maximum cooling due to increased air/

water contact.

• Cools aquarium by one of the following 

methods:

- Direct the nozzle upwards toward the 

aquarium lamp fixture to dissipate some 

of the radiant heat generated by your 

aquarium lamps.

- Direct the nozzle so that air flows 

over the surface of the water. This will 

reduce the water temperature through 

increased evaporative cooling.

• Caution must be taken when using 

electrical appliances near water. To reduce 

the risk of electric shock, be sure that 

the AQUACOOL Aquarium Cooling Fan is 

unplugged during any of the following 

situations:

- Unplug when installing the fan on or 

over your aquarium.

- Unplug when adjusting the fan, or when 

cleaning the fan housing.

- Unplug when performing aquarium 

maintenance.

- Unplug before placing your hand(s) in 

the water of the aquarium. Be sure that 

your hands are completely dry before 

plugging the AQUACOOL Aquarium Cool-

ing Fan into an appropriate grounded 

GFCI outlet.

- Unplug if the AQUACOOL Aquarium 

Cooling Fan comes into direct contact 

with water, or if any part of the AQUA-

COOL Aquarium Cooling Fan becomes 

wet.

- Unplug when not in use.

• When unplugging the AQUACOOL Aquarium 

Cooling Fan, grasp the transformer/plug 

to prevent damage to the power cord. 

Never pull on the power cord to unplug the 

transformer/plug.

• DO NOT splice, repair, or modify the power 

cord or the transformer. Inspect the power 

cord and transformer periodically for 

damage.

• For indoor use only.
• For use with aquariums only.
• Keep children and pets (other than your 

aquarium inhabitants) away from the 

AQUACOOL Aquarium Cooling Fan.

• DO NOT alter or modify this product. Con-

tact an electrician if you are unsure about 

the electrical connection.

• This unit has no user-serviceable parts. 

Do not attempt to repair this product 

yourself. Return to Zoo Med for inspection 

and repair.

The AQUACOOL Aquarium Cooling Fan must 

be plugged into a grounded GFCI (Ground Fault 

Interrupted Circuit) receptacle with a “drip 

loop” (see figure 1). The drip loop will prevent 

water from running along the power cord and 

getting the plug or wall receptacle wet. To 

create a drip loop, be sure that a portion of the 

power cord is lower than the level of the wall 

receptacle as shown in figure 1. If you are un-

sure about the electrical supply and connec-

tion, contact a qualified licensed electrician. If 

for any reason the plug or wall receptacle gets 

wet, do not grasp or unplug the power cord 

until after the power has been switched off at 

the main fuse or circuit breaker.

IMPORTANT SAFETY NOTICE!

To reduce the risk of fire, injury, or 

electric shock, read and follow these 

instructions prior to operating the 

AQUACOOL Aquarium Cooling Fan. Save 

these instructions for future reference.

AA-13E Aqua Cool

Aquarium

Power Supply Cord

Drip Loop

GFCI protected outlet

FIGURE 1

Содержание AA-13E

Страница 1: ...are completely dry before plugging the AQUACOOL Aquarium Cool ing Fan into an appropriate grounded GFCI outlet Unplug if the AQUACOOL Aquarium Cooling Fan comes into direct contact with water or if an...

Страница 2: ...vaporative cooling 6 Plug the transformer into a grounded GFCI Ground Fault Interrupted Circuit receptacle with a drip loop see figure 1 After plugging in the transformer insert the transformer jack i...

Страница 3: ...eren des K hlers am oder ber dem Aquarium Beim justieren oder reinigen des K hlers Bei der Aquarienpflege Vom Netz nehmen bevor man ins Aquarium greift Die H nde sollten vollkommen trocken sein bevor...

Страница 4: ...ren des K hlers zu vermeiden 5 Die K hld se an der Kugel des Arms anbringen Zum k hlen der Aquarienbeleuchtung Die K hld se auf die Aquarienbeleuch tung richten um die ausgehende Hitze der Lampen zu v...

Страница 5: ...e ventilateur sur ou au dessus de l aquarium D brancher pour r gler le ventilateur ou pour nettoyer le bo tier du ventilateur D brancher pour effectuer une mainte nance de l aquarium D brancher avant...

Страница 6: ...ccru par vaporation 6 Brancher le transformateur sur une prise avec un anneau d coulement voir figure 1 Une fois le transformateur bran ch ins rer le connecteur femelle dans le branchement lectrique e...

Страница 7: ...nectado durante cualquiera de las siguientes situaciones Desconecte cuando est instalando el ventilador en su pecera Desconecte cuando est ajustando o limpiando el ventilador Desconecte antes de dar m...

Страница 8: ...el transformador a la conexi n el ctrica en la parte posterior del ventilador 7 Su nuevo AQUACOOL est listo para ser utilizado Encienda el ventilador utilizando el apagador rojo Ajuste la boquilla si...

Страница 9: ...boven of naast uw aquarium aanbrengt stekker uit stopcontact verwijderen alvorens de behuizing van de koelventi lator te zuiveren stekker uit stopcontact verwijderen wanneer u onderhoudswerkzaamheden...

Страница 10: ...ker met de ventilatorbehuizing via de elektrische ingang aan de onderzijde 7 Uw nieuwe AQUACOOL Aquarium Koelventilator is nu klaar voor gebruik Zet de koelventilator aan door middel van de rode schak...

Страница 11: ...e dalla corrente quando si regola la ventola o quando se ne pulisce l alloggiamento scollegare dalla corrente du rante le operazioni di manutenzione dell acquario scollegare dalla corrente prima di im...

Страница 12: ...qua riducendone la temperatura grazie al maggiore raffreddamento per evaporazione 6 Collegare il trasformatore ad una presa con una curva di gocciolamento cfr figura 1 Dopo aver collegato il trasfor m...

Отзывы: