© Copyright 2014 Zoeller Co. All rights reserved.

LIMITED WARRANTY

Manufacturer warrants, to the purchaser and subsequent owner during 

the warranty period, every new product to be free from defects in material 

and workmanship under normal use and service, when properly used and 

maintained, for a period of three years from date of purchase by the end 

user.  Parts that fail within the warranty period, that inspections determine 

to be defective in material or workmanship, will be repaired, replaced or 

remanufactured at Manufacturer's option, provided however, that by so doing we 

will not be obligated to replace an entire assembly, the entire mechanism or the 

complete unit.  No allowance will be made for shipping charges, damages, labor 

or other charges that may occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any material 

or product that has been disassembled without prior approval of Manufacturer, 

subjected to misuse, misapplication, neglect, alteration, accident or act of 

God; that has not been installed, operated or maintained in accordance with 

Manufacturer's installation instructions; that has been exposed to outside 

substances including but not limited to the following:  sand, gravel, cement, 

mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, 

etc.), or other abrasive or corrosive substances, wash towels or feminine 

sanitary products, etc. in all pumping applications.  The warranty set out in 

the paragraph above is in lieu of all other warranties expressed or implied; and 

we do not authorize any representative or other person to assume for us any 

other liability in connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  40211, 

Attention: Product  Support Department to obtain any needed repair or 

replacement of part(s) or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, 

CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF 

EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY 

OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY 

SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied warranty, 

so the above limitation may not apply to you. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so the above 

limitation or exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have other rights 

which vary from state to state.

In those instances where damages are incurred as a result of an alleged pump failure, 

the Homeowner must retain possession of the pump for investigation purposes.

The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure. The DC 

pump, electronic controls and all the parts required for installation are included except the battery which is supplied by the user. The system is designed 

for installation in sumps with minimum of 18" diameter and 24" deep. For 18" x 22" applications, consult factory.

DESCRIPTION

The DC emergency pump system requires a good quality, 12 volt battery to obtain maximum pumping time during a power outage.  A deep-cycle, 12 

volt, 105 amp-hour marine battery or larger is recommended and will provide approximately 7½ hours of continuous pumping time in a sump pump 

installation with 8' of head pressure.  In most installations the pump runs intermittently and the battery life is extended accordingly.  Batteries with top 

terminals are recommended for ease of installation.  These batteries contain acid and proper precaution must be taken when handling.  Maximum bat-

tery size 12½" Length x 7" Width x 9½" Height.

BATTERY SELECTION

There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality.  A defective battery will never become fully 

charged and may damage the charging circuits of the  Control. It is for this reason that Zoeller offers its own line of batteries.  We offer both a Water/

Acid Deep-Cycle Battery which can run the pump continuously for over 7½ hours, and a Maintenance-Free AGM Battery, which will power the pump for 

over 3½ hours.  These times are based on continuous pumping at 10' of static head. Actual times will vary depending on static head, volume of water 

entering the pit, and the condition of the battery.

Follow these recommendations:

•  Use a B.C.I. size 27 deep-cycle battery, 175 minute reserve capacity, or larger

•  Do NOT use a “maintenance-free” battery unless it is a Gel-filled or AGM battery

•  Replace your battery every 3 years

•  Do not let corrosion build up on the battery terminals

•  Do not place your battery on a concrete floor where it will discharge faster

•  To check specific gravity, follow the instructions on a hydrometer (not applicable for Gel or AGM batteries)

PROTECT YOUR WARRANTY:  

•  Water level in batteries must be checked once a month (not applicable for Gel or AGM batteries)

THE AQUANOT

®

 BATTERY

Содержание ProPak 507 Series

Страница 1: ...upply cord and strain relief or connect conduit directly to the pump 8 Installation and servicing of electrical circuits and hardware should be performed by a qualified licensed electrician 9 Pump installation and servicing should be performed by a qualified person 10 Risk of electric shock These pumps have not been investigated for use in swimming pool and marine areas 11 According to the state o...

Страница 2: ...ay not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state In those instances where damages are incurred as a result of an alleged pump failure the Homeowner must retain possession of the pump for investigation purposes The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or ...

Страница 3: ...el or dirt 4 DO be sure that the sump is large enough to allow proper clearance for the level control switch es to operate properly 5 DO Always Disconnect Pump From Power Source Before Handling DO always connect to a separately protected and properly grounded circuit DO NOT ever cut splice or damage power cord Only splice in a watertight junction box DO NOT carry or lift pump by its power cord DO ...

Страница 4: ...lation Manual and Replacement Parts List SK2752 TYPICAL INSTALLATION EXPLODED VIEW OF PUMP SYSTEM FIGURE 1 BATTERY BOX IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE 1 MIN ABOVE CENTER OF TEE SEE INSTALLATION NOTE 3 VERIFY WEEP HOLE IS VISIBLE SEE PUMP INSTALLATION INSTRUCTIONS CHECK VALVE WEEP HOLE PROVIDED PUMP DISCHARGE 1 MIN DETAIL A SCALE 4X SEE DETAIL A FIGURE 2 ...

Страница 5: ...and anchors provided If more convenient the control charger may be set on a nearby shelf or ledge The control charger should be located 3 or 4 ft above the sump To reduce noise from vibration it is recommended that the charger be anchored with the wall bracket provided INITIAL START UP AND OPERATION 1 Test the installation for leaks by running water into the sump allowing for normal operation of t...

Страница 6: ... 1 2 PVC pipe tee 1 005645 005645 9 1 1 2 X 2 1 8 long pipe 1 150197 150197 10 1 1 2 X 8 3 4 long pipe 1 010619 010619 11 Fuse 15 Amp 1 012352 012352 CHECKLIST EXPLODED VIEW DC PUMP All installations must comply with all applicable electrical and plumbing codes including but not limited to National Electrical Code local regional and or state plumbing codes etc Not intended for use in hazardous loc...

Страница 7: ...preventing impeller from rotating 6 Pump runs but pumps water intermittently a Pump is air locking Check flow of water incoming to sump If water is entering the sump at a high velocity creating a turbulent condition a mixture of air and water may cause a complete or partial air lock and reduce or stop the flow of water in the discharge pipe b Baffle the incoming stream of water to reduce turbulenc...

Страница 8: ...ION R R GROUNDED POWER CORD LCD AC POWER SCROLL CHARGED HIGH WATER CHARGING ALARM RESET LOW BATTERY ALARM OFF ALARM CONTACTS GREEN LEAD TO FLOAT SWITCH NEGATIVE LEAD POSITIVE LEAD FIGURE 4 SK2503 FIGURE 5 SK2958 LCD DISPLAY AND KEYPAD FUNCTIONS There are two buttons on the front of the charger The scroll button is used to cycle through the information on the LCD screen The alarm reset button Can b...

Отзывы: