background image

4

© Copyright 2014 Zoeller Co. All rights reserved.

SK2750

For Installation, 

Maintenance, 

Troubleshooting 

and Service 

Checklist, 

please 

refer to 

the corresponding Pump Installation Manual and Replacement Parts List.

SK2752

TYPICAL

 INST

ALLA

TION

EXPLODED VIEW OF PUMP

 SYSTEM

FIGURE 1

BA

TTER

Y BOX

IMPOR

TANT

: OFF LEVEL

 OF 

FLOA

ASSEMBL

Y MUST

 BE 

1" MIN. 

ABOVE CENTER OF 

TEE. 

(SEE INST

ALLA

TION NOTE 3.)

VERIFY

 WEEP

 HOLE IS 

VISIBLE. (SEE PUMP

 

INST

ALLA

TION INSTRUCTIONS)

CHECK V

AL

VE

WEEP

 HOLE PROVIDED 

PUMP

 DISCHARGE

1" MIN.

DET

AIL

 "A"

(SCALE: 4X)

SEE DET

AIL

 "A"

FIGURE 2

Содержание ProPak 507 Series

Страница 1: ...upply cord and strain relief or connect conduit directly to the pump 8 Installation and servicing of electrical circuits and hardware should be performed by a qualified licensed electrician 9 Pump installation and servicing should be performed by a qualified person 10 Risk of electric shock These pumps have not been investigated for use in swimming pool and marine areas 11 According to the state o...

Страница 2: ...ay not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state In those instances where damages are incurred as a result of an alleged pump failure the Homeowner must retain possession of the pump for investigation purposes The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or ...

Страница 3: ...el or dirt 4 DO be sure that the sump is large enough to allow proper clearance for the level control switch es to operate properly 5 DO Always Disconnect Pump From Power Source Before Handling DO always connect to a separately protected and properly grounded circuit DO NOT ever cut splice or damage power cord Only splice in a watertight junction box DO NOT carry or lift pump by its power cord DO ...

Страница 4: ...lation Manual and Replacement Parts List SK2752 TYPICAL INSTALLATION EXPLODED VIEW OF PUMP SYSTEM FIGURE 1 BATTERY BOX IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE 1 MIN ABOVE CENTER OF TEE SEE INSTALLATION NOTE 3 VERIFY WEEP HOLE IS VISIBLE SEE PUMP INSTALLATION INSTRUCTIONS CHECK VALVE WEEP HOLE PROVIDED PUMP DISCHARGE 1 MIN DETAIL A SCALE 4X SEE DETAIL A FIGURE 2 ...

Страница 5: ...and anchors provided If more convenient the control charger may be set on a nearby shelf or ledge The control charger should be located 3 or 4 ft above the sump To reduce noise from vibration it is recommended that the charger be anchored with the wall bracket provided INITIAL START UP AND OPERATION 1 Test the installation for leaks by running water into the sump allowing for normal operation of t...

Страница 6: ... 1 2 PVC pipe tee 1 005645 005645 9 1 1 2 X 2 1 8 long pipe 1 150197 150197 10 1 1 2 X 8 3 4 long pipe 1 010619 010619 11 Fuse 15 Amp 1 012352 012352 CHECKLIST EXPLODED VIEW DC PUMP All installations must comply with all applicable electrical and plumbing codes including but not limited to National Electrical Code local regional and or state plumbing codes etc Not intended for use in hazardous loc...

Страница 7: ...preventing impeller from rotating 6 Pump runs but pumps water intermittently a Pump is air locking Check flow of water incoming to sump If water is entering the sump at a high velocity creating a turbulent condition a mixture of air and water may cause a complete or partial air lock and reduce or stop the flow of water in the discharge pipe b Baffle the incoming stream of water to reduce turbulenc...

Страница 8: ...ION R R GROUNDED POWER CORD LCD AC POWER SCROLL CHARGED HIGH WATER CHARGING ALARM RESET LOW BATTERY ALARM OFF ALARM CONTACTS GREEN LEAD TO FLOAT SWITCH NEGATIVE LEAD POSITIVE LEAD FIGURE 4 SK2503 FIGURE 5 SK2958 LCD DISPLAY AND KEYPAD FUNCTIONS There are two buttons on the front of the charger The scroll button is used to cycle through the information on the LCD screen The alarm reset button Can b...