background image

3

© Copyright 2014 Zoeller Co. All rights reserved.

  1.   Electrical wiring and protection must be in accordance with National   

  Electrical Code and any other applicable state and local electrical   

 requirements.

  2.   All installations require a basin cover to prevent debris from falling into 

the basin and to prevent accidental injury.

  3.   Securely tape or clamp power cord to discharge pipe, clear of the float 

mechanism(s).

  4.  Use full-size discharge pipe.

  5.   Basin must be in accordance with applicable codes and specifications.
  6.   Pump must be level and float mechanism(s) clear of sides of basin 

before starting pump.  Float switch may be repositioned as needed.

  7.  Basin must be clean and free of debris after installation.
  8.   Gate Valve or Ball Valve to be supplied by installer and installed 

according to any and all codes.

  9.  Gas tight seals required to contain gases and odors.
  10.   Vent gases and odors to the atmosphere through vent pipe.
  11.    Install Zoeller Pump Stand (Model 10-2421) under pump to  

  provide a settling basin.

RECOMMENDED INSTALLATION FOR ALL APPLICATIONS

EASY DO'S & DON'TS FOR INSTALLING A SUMP PUMP

   1.  DO read thoroughly all installation material provided with the system.
   2.  DO inspect system for any visible damage caused by shipping.  Contact 

dealer if system appears to be damaged.

   3.  DO clean all debris from the sump.  Be sure that the pump will have a hard, 

flat surface beneath it.  DO NOT install on sand, gravel or dirt.

   4.  DO be sure that the sump is large enough to allow proper clearance for the 

level control switch(es) to operate properly.

   5.  DO Always Disconnect Pump From Power Source Before Handling.

    DO always connect to a separately protected and properly grounded circuit.

    DO NOT ever cut, splice, or damage power cord (Only splice in a watertight 

junction box).

    DO NOT carry or lift pump by its power cord.

    DO NOT use an extension cord with a sump pump.

   6.  DO install a union in the discharge line.

    DO NOT use a discharge pipe smaller than the pump discharge.
  7.  DO NOT use a sump pump as a trench or excavation pump, or for pumping 

sewage, gasoline, or other hazardous liquids.

  8.  DO test system immediately after installation to be sure that the system is 

working properly.

  9.  DO cover sump with an adequate sump cover.
  10.  DO review all applicable local and national codes and verify that the installation 

conforms to each of them.

  11.  DO consult manufacturer for clarifications or questions.

  12.  DO inspect and test system for proper operations at least every three months.

The DC controller is equipped with a 10 amp charger for maintaining the battery in a ready state and recharging the battery after use when AC power 

is restored.  Time for recharge depends upon the amount of power consumed by the pumping cycle during the AC power interruption.  The system 

may return to the charged LED position in a very short period of time.  A completely drained battery may require up to 24 hours for full recharge.  

PERFORMANCE

Discharge Feet of Head

5

10

15

17.5

Flow Gal. per min.

23

15

5

Shut-off Head

The DC pump performance with fully charged 12V battery

Содержание ProPak 507 Series

Страница 1: ...upply cord and strain relief or connect conduit directly to the pump 8 Installation and servicing of electrical circuits and hardware should be performed by a qualified licensed electrician 9 Pump installation and servicing should be performed by a qualified person 10 Risk of electric shock These pumps have not been investigated for use in swimming pool and marine areas 11 According to the state o...

Страница 2: ...ay not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state In those instances where damages are incurred as a result of an alleged pump failure the Homeowner must retain possession of the pump for investigation purposes The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or ...

Страница 3: ...el or dirt 4 DO be sure that the sump is large enough to allow proper clearance for the level control switch es to operate properly 5 DO Always Disconnect Pump From Power Source Before Handling DO always connect to a separately protected and properly grounded circuit DO NOT ever cut splice or damage power cord Only splice in a watertight junction box DO NOT carry or lift pump by its power cord DO ...

Страница 4: ...lation Manual and Replacement Parts List SK2752 TYPICAL INSTALLATION EXPLODED VIEW OF PUMP SYSTEM FIGURE 1 BATTERY BOX IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE 1 MIN ABOVE CENTER OF TEE SEE INSTALLATION NOTE 3 VERIFY WEEP HOLE IS VISIBLE SEE PUMP INSTALLATION INSTRUCTIONS CHECK VALVE WEEP HOLE PROVIDED PUMP DISCHARGE 1 MIN DETAIL A SCALE 4X SEE DETAIL A FIGURE 2 ...

Страница 5: ...and anchors provided If more convenient the control charger may be set on a nearby shelf or ledge The control charger should be located 3 or 4 ft above the sump To reduce noise from vibration it is recommended that the charger be anchored with the wall bracket provided INITIAL START UP AND OPERATION 1 Test the installation for leaks by running water into the sump allowing for normal operation of t...

Страница 6: ... 1 2 PVC pipe tee 1 005645 005645 9 1 1 2 X 2 1 8 long pipe 1 150197 150197 10 1 1 2 X 8 3 4 long pipe 1 010619 010619 11 Fuse 15 Amp 1 012352 012352 CHECKLIST EXPLODED VIEW DC PUMP All installations must comply with all applicable electrical and plumbing codes including but not limited to National Electrical Code local regional and or state plumbing codes etc Not intended for use in hazardous loc...

Страница 7: ...preventing impeller from rotating 6 Pump runs but pumps water intermittently a Pump is air locking Check flow of water incoming to sump If water is entering the sump at a high velocity creating a turbulent condition a mixture of air and water may cause a complete or partial air lock and reduce or stop the flow of water in the discharge pipe b Baffle the incoming stream of water to reduce turbulenc...

Страница 8: ...ION R R GROUNDED POWER CORD LCD AC POWER SCROLL CHARGED HIGH WATER CHARGING ALARM RESET LOW BATTERY ALARM OFF ALARM CONTACTS GREEN LEAD TO FLOAT SWITCH NEGATIVE LEAD POSITIVE LEAD FIGURE 4 SK2503 FIGURE 5 SK2958 LCD DISPLAY AND KEYPAD FUNCTIONS There are two buttons on the front of the charger The scroll button is used to cycle through the information on the LCD screen The alarm reset button Can b...

Отзывы: