Zoeller 53 Series Скачать руководство пользователя страница 2

2

© Copyright 2019 Zoeller

®

 Co. All rights reserved.

in lieu of all other warranties expressed or implied; and we do not authorize any 

representative or other person to assume for us any other liability in connection 

with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  40211, Attention: 

Customer Service Department to obtain any needed repair or replacement of 

part(s) or additional information pertaining to our warranty.

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, 
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED 
OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR A 
PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE 
DURATION OF THE EXPRESSED WARRANTY.

Some states do not allow limitations on the duration of an implied warranty, so 

the above limitation may not apply to you. Some states do not allow the exclusion 

or limitation of incidental or consequential damages, so the above limitation or 

exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have other rights 

which vary from state to state.

Limited Warranty

Manufacturer warrants, to the purchaser and subsequent owner during the warranty 

period, every new product to be free from defects in material and workmanship 

under normal use and service, when properly used and maintained, for a period of 

three years from the date of purchase.  Proof of purchase is required. Parts that fail 

within the warranty period, that inspections determine to be defective in material 

or workmanship, will be repaired, replaced or remanufactured at Manufacturer's 

option, provided however, that by so doing we will not be obligated to replace an 

entire assembly, the entire mechanism or the complete unit.  No allowance will 

be made for shipping charges, damages, labor or other charges that may occur 

due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any material 

or product that has been disassembled without prior approval of Manufacturer, 

subjected to misuse, misapplication, neglect, alteration, accident or act of 

nature; that has not been installed, operated or maintained in accordance with 

Manufacturer's installation instructions; that has been exposed to outside 

substances including but not limited to the following:  sand, gravel, cement, mud, 

tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other 

abrasive or corrosive substances, wash towels or feminine sanitary products, 

etc. in all pumping applications.  The warranty set out in the paragraph above is 

  

ELECTRICAL PRECAUTIONS-

 Before servicing a pump, always shut off the main power breaker and then unplug the pump - making sure 

you are wearing insulated protective sole shoes and not standing in water. Under flooded conditions, contact your local electric company or a qualified 

licensed electrician for disconnecting electrical service prior to pump removal.

 

Submersible pumps contain oils which becomes pressurized and hot under operating conditions. 

Allow 2-1/2 hours after disconnecting before 

attempting service.

If the above checklist does not uncover the problem, consult the factory. Do not attempt to service or otherwise disassemble pump. Service must be performed by 

Zoeller Authorized Service and Warranty Centers. Go to www.zoellerpumps.com

 to find the Authorized Service Center in your area.

SERVICE CHECKLIST

EASY DO’S & DON'T’S FOR INSTALLING A SUMP PUMP

  

1. 

DO

 read thoroughly all installation material provided with the pump.

   2. 

DO

 inspect pump for any visible damage caused by shipping.  Contact dealer 

if pump appears to be damaged.

   3. 

DO

 clean all debris from the sump.  Be sure that the pump will have a hard, 

flat surface beneath it.  DO NOT install on sand, gravel or dirt.

   4. 

DO

 be sure that the sump is large enough to allow proper clearance for the 

level control switch(es) to operate properly.

   5. 

DO Always Disconnect Pump From Power Source Before Handling.

  

DO

 always connect to a separately protected and properly grounded circuit.

  

DO NOT

 ever cut, splice, or damage power cord (Only splice in a watertight 

junction box).

  

DO NOT

 carry or lift pump by its power cord.

  

DO NOT

 use an extension cord with a sump pump.

   6. 

DO

 install a check valve and a union in the discharge line.

  

DO NOT

 use a discharge pipe smaller than the pump discharge.

 7. 

DO NOT

 use a sump pump as a trench or excavation pump, or for pumping 

sewage, gasoline, or other hazardous liquids.

 8. 

DO

 test pump immediately after installation to be sure that the system is 

working properly.

 9. 

DO 

cover sump with an adequate sump cover.

 10. 

DO

 review all applicable local and national codes and verify that the installation 

conforms to each of them.

 11. 

DO

 consult manufacturer for clarifications or questions.

 12. 

DO

 consider a two pump system with an alarm where an installation may become 

overloaded or primary pump failure would result in property damages.

 13. 

DO

 consider a D.C. Backup System where a sump or dewatering pump is 

necessary for the prevention of property damages from flooding due to A.C. 

power disruptions, mechanical or electrical problems or system overloading.

   14. 

DO 

inspect and test system for proper operations at least every three months.

CONDITION

COMMON CAUSES

A.  Pump will not start or run.

Check fuse, low voltage, overload open, open or incorrect wiring, open switch, impeller or seal bound mechanically, 

defective capacitor or relay when used, motor or wiring shorted. Float assembly held down. Switch defective, 

damaged, or out of adjustment.

B.  Motor overheats and trips overload or 

blows fuse.

Incorrect voltage, negative head (discharge open lower than normal) impeller or seal bound mechanically, defective 

capacitor or relay, motor shorted.

C.  Pump starts and stops too often.

Float tight on rod, check valve stuck or none installed in long distance line, overload open, level switch(s) defective, 

sump pit too small.

D.  Pump will not shut off.

Debris under float assembly, float or float rod bound by pit sides or other, switch defective, damaged or out of adjustment.

E.  Pump operates but delivers little or no 

water.

Check strainer housing, discharge pipe, or if check valve is used vent hole must be clear. Discharge head exceeds 

pump capacity. Low or incorrect voltage. Incorrect motor rotation. Capacitor defective. Incoming water containing 

air or causing air to enter pumping chamber.

F.  Drop in head and/or capacity after a 

period of use.

Increased pipe friction, clogged line or check valve. Abrasive material and adverse chemicals could possibly 

deteriorate impeller and pump housing. Check line. Remove base and inspect.

In instances where property damages are incurred as a result of an alleged product failure, 

the property owner must retain possession of the product for investigation purpose.  

Содержание 53 Series

Страница 1: ...hese pumps have not been investigated for use in swimming pool and marine areas 11 Prop65WarningforCaliforniaresidents CancerandReproductiveHarm www P65Warnings ca gov 1 Check to be sure your power so...

Страница 2: ...Zoeller Authorized Service and Warranty Centers Go to www zoellerpumps com to find the Authorized Service Center in your area SERVICE CHECKLIST EASY DO S DON T S FOR INSTALLING A SUMP PUMP 1 DO read...

Страница 3: ...on front page Water stream will be visible from this hole during pump run periods 5 Securely tape or clamp power cord to discharge pipe clear of the float mechanism s 6 Use full size discharge pipe 7...

Страница 4: ...tion All three phase pumps require motor starting devices with motor overload protection See FM0486 for duplex installations Pumps must be installed in accordance with the National Electrical Code and...

Страница 5: ...usar tuber a y empalmes r gidos y que el foso tenga 45 cm 18 pulg o m s de di metro 3 Informaci n Objetivo del agujero de ventilaci n Es necesario que todas las bombas sumergibles de sumidero efluent...

Страница 6: ...de retenci n y una uni n en la tuber a de descarga JAM S use una tuber a de descarga de menor tama o que la descarga de la bomba 7 JAM S use una bomba de sumidero como una bomba excavadora o para zanj...

Страница 7: ...herm ticos contra gases son necesarios a fin de contener los gases y olores 13 Ventile los gases y olores a la atm sfera a trav s del tubo de ventilaci n Debe cumplir con los c digos locales pero no e...

Страница 8: ...quite el cable de alimentaci n el ctrica ni el dispositivo de alivio de tensi n y no conecte un conductor directamente a la bomba ADVERTENCIA La instalaci n y verificaci n de los circuitos el ctricos...

Страница 9: ...tallateur est responsable de l installation des pompes automatiques avec des interrupteurs niveauvariableoudespompesnon automatiquesutilisantdesinterrupteurs auxiliaires niveau variable et il doit s a...

Страница 10: ...qui varient d une province l autre GARANTIE LIMIT E Le fabricant garantit l acheteur et au propri taire ult rieur pendant la p riode de garantie tout produit neuf contre tout vice de mat riel et de m...

Страница 11: ...s r glements applicables 8 Avantlamiseenservice lapompedoit tredeniveauetlem canismeduflotteur ne doit pas toucher les bords du puits 9 Apr s l installation le puits doit tre propre et ne doit pas con...

Страница 12: ...ache Plage de pompage 5 10 15 20 22 9 13 5 18 22 24 127 mm 5 po min 559 mm 22 po max SK305 Interrupteur 20 amps mod les WD et WH min max 011835 Instructions de branchement triphas AVERTISSEMENT POUR D...

Отзывы: