6
AQUANOT
®
FIT FLOAT SWITCH
FIGURE 3
SK3186
FIT CONTROLLER FUNCTIONS
There are two buttons on the front of the controller.
-
Silence/Reset
• Can be pressed to silence current alarms for 24 hours.
•
Can be held for longer than 3 seconds to reset alarm. Reset will clear flashing light on unit.
-
Test
• Will run the pump to determine if amp draw of pump is in range.
• Controller is factory programmed to self-test the pump for several seconds every 24 hours.
• Pressing the test button will start the 24-hour timer for self-testing.
AQUANOT FIT
Solid
Flashing
Off
System Ready
No Faults (Green) AC off with no faults (Green)
--
Battery
Charged (Green)
Low Battery (Red)
No AC Power
Charging (Yellow)
Bad Battery (Red)
DC pump
Pump Ran (Yellow)
Pump Running (Yellow)
--
Pump Fault (Red)
Float Status
High Water (Red)
Float Fault (Red)
--
Z Control
Connected
Searching
Broadcasting SSID or Dormant
The LEDs will display information about the controller.
© Copyright 2019 Zoeller
®
Co. All rights reserved.
LOCKING PIN MUST BE
INSTALLED UNDER FLOAT
ROD IN THIS LOCATION.
MOLEX 4-PIN CONNECTOR
MOLEX 2-PIN CONNECTOR
FIG. 4
DC PUMP
DISCHARGE TEE
REDUCER FITTING
CLAMP
CHECK VALVE ASSEMBLY
CLAMP
SK2962
FIGURE 4