FM3120
0119
Supersedes
1218
12 VOLT DC BATTERY BACKUP PUMP
INSTALLATION INSTRUCTIONS
PREINSTALLATION CHECKLIST
1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are damaged, contact your dealer before using.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future
reference.
SEE BELOW FOR
LIST OF WARNINGS
1. Testing for ground. As a safety measure each electrical outlet should
be checked for ground using an Underwriters Laboratory listed circuit
analyzer, which will indicate if the power, neutral and ground wires are
correctly connected to your outlet. If they are not, call a qualified, licensed
electrician.
2. For your protection, always disconnect the power supply from its power
source before handling the components of your DC backup pump or the
primary pump.
3. Installation and servicing of electrical circuits and hardware should be
performed by a qualified, licensed electrician.
4. All electrical and safety codes must be followed including the National
Electrical Code and all applicable local codes.
5.
It is the owner’s responsibility to check the battery and battery
connection at least once a month. Batteries contain acid, and
caution must be taken when handling.
6. Risk of electric shock. These pumps have not been investigated
for use
in swimming pools and marine areas.
7. Prop65 Warning for california residents: Cancer and Reproductive Harm-
www.P65Warning.ca.gov.
1. Make sure there is a properly grounded 115 V receptacle available. Do
not use primary pump circuit.
The location must be within 6' (1.8 m) of
the control box and battery. The power supply for your DC control system
plugs directly into the 115 V outlet.
DO NOT USE AN EXTENSION CORD.
2. Make sure the 115 V electrical supply circuit is equipped with fuses or
circuit breakers of proper capacity.
3. DC emergency pumps are designed for handling clear water. Do not use
in septic tanks to pump effluent or in sewage pits to pump sewage.
4. Repair and service of your DC backup system should be performed by
an authorized service station.
5. The installation of DC automatic backup pumps requires the use of a
variable level float switch for operation. It is the responsibility of the
installing party to ensure that the float switch will not hang up on the
pump apparatus or pit peculiarities and is secured so the pump will turn
“on” and “off”. It is recommended that the pit be 18" (45.7 cm) in diameter
or larger to accommodate both a primary and a DC backup pump.
6. For indoor use only.
CAUTION
SEE BELOW FOR
LIST OF CAUTIONS
REFER TO WARRANTY ON PAGE 2.
CAUTION
Turbulence caused by high-velocity incoming
water can cause sump pumps to airlock. If this condition exists,
the incoming water must be baffled to avoid excessive turbulence.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.