background image

FOR

 DEEP

 WELL

 APPLICA

TIONS

 2

5 -

 7

0 FT

.

FOR

 DEEP

 WELL

 APPLICA

TIONS

 2

5 -

 7

FT

.

16

© 2020. All rights reserved.

17

© 2020. All rights reserved.

CARE AND MAINTENANCE

Winterizing

  CAUTION:  

Drain the entire system if there is 

danger of freezing. A drain plug is provided at the 

bottom of the pump for this purpose.

IL0345

1

PREVENT 

PUMP 

DAMAGE!

Remove plug in 

freezing weather

Please review the following troubleshooting questions before returning a pump as defective.
If you have any questions, please call Customer Service at (800) 584-8089.

MODEL

LIQUID PUMP

LR90197

US

REV

DATE CODE:/CÓDIGO DE FECHA

Made in USA • Hecho en EE.UU.

Kendallville, IN 46755 • USA

QUICK TROUBLE-SHOOTING CHECKLIST

20

20

20

20

RESETRESET

TESTTEST

IL1381

C

US

LR90197

UL Std. No. 778

ENCLOSURE 3

starwatersystems.com

Pump:

JHU10

Rev:

B

Motor:

98U1071

HP:

1

PH

1

Hz

60

Volts

115/230

S.F.

1.2

Amps

14/7

S.F. Amps:

14/7

RPM

3450

Type

C

Duty:

Cont.

Temp

65C

KVA Code

G

Frame

56L

Ins Class

B

Factory prewired for 230V

Thermally protected automatically

Check voltage of power source

Use copper conductors only

  

  ELECTRICAL HAZARD  

Improper installation may result in fi re, explosion, electrical short or injury. Replace all covers 

before operating. Ground motor in accordance with local and national electrical codes. 

Disconnect power source before touching internal parts. Motors equipped with automatic 

protection may restart without warning.

See instruction manual for proper installation procedure.

Se reporter au manuel d’instructions pour suivre la procédure adéquate d’installation.

Consulte el instructive para conocer el procedimiento de instalación correcto.

L1

L2

A

B

L1

L2

A

B

IL0180

YELLOW

115 VOLT

SINGLE PHASE

LINE

230 VOLT

SINGLE PHASE

LINE

WHITE

GRAY

RED

TAN

YELLOW

WHITE

GRAY

RED

TAN

DATE CODE: 

0418*

                                                                                      

Made in USA

IL1406

IL1401

1.   Check date code to make sure pump is within 

warranty period. Date code is the month and 

the year. 

      (Example: 0318 is March of 2018. Date Code is 

found on the top of the pump.)

2.   Make certain that the power source matches the 

pump requirements. This pump has a dual voltage 

motor and can run on 115 V or 230 V. This pump is 

pre-wired at the factory to run on 230 V.

3.    If pump does not run, check the GFI or breaker 

panel switch to make sure it is in full operation.

4.   If the pump runs all the time, make sure the 

pump has been primed correctly. If pump is not 

holding the prime, inspect check valve, foot 

valve, and piping, then reprime.

5.   If the pump runs but won’t shut off, check 

pressure switch.

Содержание 1463-0006

Страница 1: ...oblems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE Zoeller is a registered trade...

Страница 2: ...nd can run on 115 V or 230 V It is factory pre set to run on 230 V ELECTRICAL SHOCK ALERT SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble operate or inst...

Страница 3: ...GA 50 100 115 V 230 V 10 GA 14 GA 100 150 115 V 230 V 10 GA 12 GA 150 200 115 V 230 V 8 GA 12 GA 200 300 115 V 230 V 6 GA 10 GA Fuse Size 115 V 230 V Amps 30 15 Pipe And Fittings Use galvanized steel...

Страница 4: ...ction IL1395 Tape 1 IL1396 2 2 Finish the connection to your well with additional pipe and fittings as needed PUMP TO PRESSURE TANK CONNECTION DISCHARGE PIPE DEEP WELL 1 To begin the connection to the...

Страница 5: ...ressure tanks will have a 1 inch inlet elbow on the bottom Connect to this elbow with a 1 in MPT x 1 in slip glue adapter and short piece of pipe 2 Install a 1 in elbow IL1365 Glue Adapter Pipe IL1366...

Страница 6: ...4 in opening on the side of the flow control and remove the switch cover C US LR90197 UL Std No 778 ENCLOSURE 3 starwatersystems com Pump JHU10 Rev B Motor 98U1071 HP 1 PH 1 Hz 60 Volts 115 230 S F 1...

Страница 7: ...rce Use copper conductors only ELECTRICAL HAZARD Improper installation may result in fire explosion electrical short or injury Replace all covers before operating Ground motor in accordance with local...

Страница 8: ...d register on the gauge mounted on the pump body If pressure does not build repeat priming operation All air must be vented from the drive and suction pipes as well as the body before the pump will pr...

Страница 9: ...place all covers before operating Ground motor in accordance with local and national electrical codes Disconnect power source before touching internal parts Motors equipped with automatic protection m...

Страница 10: ...nted for two years from the date of purchase Subject to the conditions hereinafter set forth the manufacturer will repair or replace to the original consumer any portion of the product which proves de...