background image

FOR

 DEEP

 WELL

 APPLICA

TIONS

 2

5 -

 7

0 FT

.

FOR

 DEEP

 WELL

 APPLICA

TIONS

 2

5 -

 7

FT

.

18

© 2020. All rights reserved.

19

© 2020. All rights reserved.

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

Little or no 

discharge

1.  Casing not initially filled with water

1.   Fill pump casing

2. Suction lift too high, or too long

2.    Move pump closer to water source

3. Hole or air leak in suction line

3.   Repair or replace. Use pipe tape and 

pipe sealing compound.

4. Foot valve too small

4.    Match foot valve to piping or install one 

size larger foot valve.

5.  Foot valve or suction line not submerged 

deep enough in water

5.   Submerge lower in water

6. Motor wired incorrectly

6.  Check wiring diagram

7. Casing gasket leaking

7. Replace

8.  Suction or discharge line valves closed

8. Open

Pump will not 

deliver water 

or develop 

pressure

1. No priming water in casing

1.   Fill pump casing

2.  Leak in suction line

2.   Repair or replace

3.  Discharge line is closed, and priming air 

has nowhere to go

3.   Open ball valve

4.  Suction line (or valve) is closed

4.   Open

5.  Foot valve is leaking

5.   Replace foot valve

6.  Suction screen clogged

6.   Clean or replace

Loss of suction

1. Air leak in suction line

1.   Repair or replace

2. Suction lift too high

2.   Lower suction lift, install foot valve, and 

prime

3.  Insufficient inlet pressure or suction head

3.    Increase inlet pressure by adding more 

water to tank or increasing back pressure

4.  Clogged foot valve or strainer

4.   Unclog

Pump vibrates 

and/or makes 

excessive noise

1.  Mounting plate or foundation not rigid 

enough

1. Reinforce

2.  Foreign material in pump

2.  Disassemble pump and clean

3.  Impeller damaged

3. Replace

4.  Worn motor bearings

4.   Replace

Pump will not 

start or run

1.  Improperly wired

1.  Check wiring diagram on motor

2.  Blown fuse or open circuit breaker

2.  Replace fuse or close circuit breaker

3.  Loose or broken wiring

3.  Tighten connections, replace broken 

wiring

4.  Stone or foreign object lodged in impeller 4.  Disassemble pump and remove foreign 

object

5.  Motor shorted out

5. Replace

6.   Thermal overload has opened circuit

6.  Allow unit to cool. Restart after reason for 

overload has been determined.

WARRANTY

REPAIR PARTS

ITEM

DESCRIPTION

PART NO.

1

Repair Kit includes 

impeller, diffuser, rotary 

seal, quadraseal, and 

diffuser rubber

148140

2

Flow Control Assembly

134349

7

8

This product is warranted for two years from the date of purchase. Subject to the conditions hereinafter set 

forth, the manufacturer will repair or replace to the original consumer any portion of the product which proves 

defective due to defective materials or workmanship. To obtain warranty service, contact the dealer from whom 

the product was purchased. The manufacturer retains the sole right and option to determine whether to repair 

or replace defective equipment, parts, or components. Damage due to conditions beyond the control of the 

manufacturer is not covered by this warranty.
THIS WARRANTY WILL NOT APPLY: (a) To defects or malfunctions resulting from failure to properly install, 

operate, or maintain the unit in accordance with printed instructions provided; (b) to failures resulting from 

abuse, accident, or negligence, or use of inappropriate chemicals or additives in the water; (c) to normal 

maintenance services and the parts used in connection with such service; (d) to units which are not installed 

in accordance with normal applicable local codes, ordinances, and good trade practices; and (e) if the unit is 

used for purposes other than for what it was designed and manufactured.
RETURN OF WARRANTED COMPONENTS: Any item to be repaired or replaced under this warranty must be 

returned to the manufacturer at Kendallville, Indiana or such other place as the manufacturer may designate, 

freight prepaid.
THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND MAY 

NOT BE EXTENDED OR MODIFIED BY ANYONE. ANY IMPLIED WARRANTIES SHALL BE LIMITED TO 

THE PERIOD OF THE LIMITED WARRANTY AND THEREAFTER ALL SUCH IMPLIED WARRANTIES ARE 

DISCLAIMED AND EXCLUDED. THE MANUFACTURER SHALL NOT, UNDER ANY CIRCUMSTANCES, BE 

LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, SUCH AS, BUT NOT LIMITED TO 

DAMAGE TO, OR LOSS OF, OTHER PROPERTY OR EQUIPMENT, LOSS OF PROFITS, INCONVENIENCE, 

OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY TYPE OR NATURE. THE LIABILITY 

OF THE MANUFACTURER SHALL NOT EXCEED THE PRICE OF THE PRODUCT UPON WHICH SUCH 

LIABILITY IS BASED.

This warranty gives you specific legal rights, and you may have other rights which vary from state to 

state. Some states do not allow limitations on duration of implied warranties or exclusion of incidental or 

consequential damages, so the above limitations may not apply to you.

1

2

In those instances where damages are incurred as a result of an alleged pump failure, the Homeowner 

must retain possession of the pump for investigation purposes.

Содержание 1463-0006

Страница 1: ...oblems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE Zoeller is a registered trade...

Страница 2: ...nd can run on 115 V or 230 V It is factory pre set to run on 230 V ELECTRICAL SHOCK ALERT SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble operate or inst...

Страница 3: ...GA 50 100 115 V 230 V 10 GA 14 GA 100 150 115 V 230 V 10 GA 12 GA 150 200 115 V 230 V 8 GA 12 GA 200 300 115 V 230 V 6 GA 10 GA Fuse Size 115 V 230 V Amps 30 15 Pipe And Fittings Use galvanized steel...

Страница 4: ...ction IL1395 Tape 1 IL1396 2 2 Finish the connection to your well with additional pipe and fittings as needed PUMP TO PRESSURE TANK CONNECTION DISCHARGE PIPE DEEP WELL 1 To begin the connection to the...

Страница 5: ...ressure tanks will have a 1 inch inlet elbow on the bottom Connect to this elbow with a 1 in MPT x 1 in slip glue adapter and short piece of pipe 2 Install a 1 in elbow IL1365 Glue Adapter Pipe IL1366...

Страница 6: ...4 in opening on the side of the flow control and remove the switch cover C US LR90197 UL Std No 778 ENCLOSURE 3 starwatersystems com Pump JHU10 Rev B Motor 98U1071 HP 1 PH 1 Hz 60 Volts 115 230 S F 1...

Страница 7: ...rce Use copper conductors only ELECTRICAL HAZARD Improper installation may result in fire explosion electrical short or injury Replace all covers before operating Ground motor in accordance with local...

Страница 8: ...d register on the gauge mounted on the pump body If pressure does not build repeat priming operation All air must be vented from the drive and suction pipes as well as the body before the pump will pr...

Страница 9: ...place all covers before operating Ground motor in accordance with local and national electrical codes Disconnect power source before touching internal parts Motors equipped with automatic protection m...

Страница 10: ...nted for two years from the date of purchase Subject to the conditions hereinafter set forth the manufacturer will repair or replace to the original consumer any portion of the product which proves de...

Отзывы: