Zoeller 1463-0006 Скачать руководство пользователя страница 7

FOR

 DEEP

 WELL

 APPLICA

TIONS

 2

5 -

 7

0 FT

.

FOR

 DEEP

 WELL

 APPLICA

TIONS

 2

5 -

 7

FT

.

12

© 2020. All rights reserved.

13

© 2020. All rights reserved.

Wire from 

motor

Wire from 

power

supply

7

IL1376

Wire from 

motor

Pressure

switch

Strain

relief

6

6.   Insert an electrical wire strain relief into the 

opening in the opposite side of the pressure 

switch.

7.  Thread the cable from the power supply through 

the strain relief and tighten both screws on the 

strain relief. Do not crush wire. 

Wire 

from 

motor

Wire from 

power

supply

Ground Screws

Green 

ground 

wire

9

Outside

terminal

Two wires 

from power 

supply

Outside

terminal

Wire from 

motor

Wire from 

power

supply

8

9.   Connect the green ground wire from the power 

supply to the remaining green ground screw in 

the pressure switch, and re-attach the pressure 

switch cover. 

8.   Connect the two wires from the power supply to 

the two outside terminals on the pressure switch. 

A

B

L1

L2

IL2194 B

230 V

GRAY

RED

A

B

L1

L2

IL2195 A

230 V

GRAY

RED

A

B

L1

L2

IL2196 A

115 V

GRAY RED

A B

L1

L2

IL1354 A

115 V

GRAY

RED

C

US

LR90197

UL Std. No. 778

ENCLOSURE 3

starwatersystems.com

Pump:

JHU10

Rev:

B

Motor:

98U1071

HP:

1

PH

1

Hz

60

Volts

115/230

S.F.

1.2

Amps

14/7

S.F. Amps:

14/7

RPM

3450

Type

C

Duty:

Cont.

Temp

65C

KVA Code

G

Frame

56L

Ins Class

B

Factory prewired for 230V

Thermally protected automatically

Check voltage of power source

Use copper conductors only

  

  ELECTRICAL HAZARD  

Improper installation may result in fi re, explosion, electrical short or injury. Replace all covers 

before operating. Ground motor in accordance with local and national electrical codes. 

Disconnect power source before touching internal parts. Motors equipped with automatic 

protection may restart without warning.

See instruction manual for proper installation procedure.

Se reporter au manuel d’instructions pour suivre la procédure adéquate d’installation.

Consulte el instructive para conocer el procedimiento de instalación correcto.

L1

L2

A

B

L1

L2

A

B

IL0180

YELLOW

115 VOLT

SINGLE PHASE

LINE

230 VOLT

SINGLE PHASE

LINE

WHITE

GRAY

RED

TAN

YELLOW

WHITE

GRAY

RED

TAN

DATE CODE: 

0418*

                                                                                      

Made in USA

1

To change from 230 V to 115 V

1.  The motor of this pump is dual voltage and can 

run on either 115 V or 230 V. In general, 230 V is 

more economical to run and requires a smaller 

wire size. 

NOTE: This pump is pre-wired at the factory to 

run on 230 V.

2b

2a

b. 

Pull the red wire with the female flag 

connector from the “B” terminal. Place it to the 

right on the “L2” terminal spade post.

2a.   For 115 V service, change the following wires on 

the terminal board:

a.  Using a pair of needle nose pliers, pull the 

gray wire with the female flag connector from 

the “B” terminal spade post. Place it to the left 

on the “A” terminal spade post.

2c

c.  Reinstall the rear motor cover. 

NOTE: To change voltage from 115 V to 230 V, 

simply reverse instructions above.

230 V

115 V

Содержание 1463-0006

Страница 1: ...oblems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE Zoeller is a registered trade...

Страница 2: ...nd can run on 115 V or 230 V It is factory pre set to run on 230 V ELECTRICAL SHOCK ALERT SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble operate or inst...

Страница 3: ...GA 50 100 115 V 230 V 10 GA 14 GA 100 150 115 V 230 V 10 GA 12 GA 150 200 115 V 230 V 8 GA 12 GA 200 300 115 V 230 V 6 GA 10 GA Fuse Size 115 V 230 V Amps 30 15 Pipe And Fittings Use galvanized steel...

Страница 4: ...ction IL1395 Tape 1 IL1396 2 2 Finish the connection to your well with additional pipe and fittings as needed PUMP TO PRESSURE TANK CONNECTION DISCHARGE PIPE DEEP WELL 1 To begin the connection to the...

Страница 5: ...ressure tanks will have a 1 inch inlet elbow on the bottom Connect to this elbow with a 1 in MPT x 1 in slip glue adapter and short piece of pipe 2 Install a 1 in elbow IL1365 Glue Adapter Pipe IL1366...

Страница 6: ...4 in opening on the side of the flow control and remove the switch cover C US LR90197 UL Std No 778 ENCLOSURE 3 starwatersystems com Pump JHU10 Rev B Motor 98U1071 HP 1 PH 1 Hz 60 Volts 115 230 S F 1...

Страница 7: ...rce Use copper conductors only ELECTRICAL HAZARD Improper installation may result in fire explosion electrical short or injury Replace all covers before operating Ground motor in accordance with local...

Страница 8: ...d register on the gauge mounted on the pump body If pressure does not build repeat priming operation All air must be vented from the drive and suction pipes as well as the body before the pump will pr...

Страница 9: ...place all covers before operating Ground motor in accordance with local and national electrical codes Disconnect power source before touching internal parts Motors equipped with automatic protection m...

Страница 10: ...nted for two years from the date of purchase Subject to the conditions hereinafter set forth the manufacturer will repair or replace to the original consumer any portion of the product which proves de...

Отзывы: