background image

2

  1.  Read all instructions before deploying unit.

 2. Be sure the installation does not exceed a maximum vertical lift of 24' (7.3 m).

  3.  Test operation of pump per Helpful Hint No. 5.

HELPFUL HINTS

  4.  Plug pump into a properly grounded, constant voltage source.

  5.  Do not plug into a device that runs intermittently.

  6.  Obtain model number and date code from the pump name plate prior 

to calling factory.

  1.  DO read all installation material included with the pump.

  2.   DO inspect unit for any visible damage caused by shipping. Contact dealer 

if unit appears to be damaged.

  3.  DO clean all debris from the pump reservoir.   

  4.  DO always disconnect pump from power source before handling. DO 

always connect to a separately protected and properly grounded ground 

fault protected circuit. DO NOT ever cut, splice or damage power cord. 

DO NOT carry or lift pump by its power cord. 

DO’S  AND  DON'TS  FOR  DEPLOYING  A  UNIT

  5.  DO NOT use

 

a discharge pipe smaller than the diameter of the hose kit.

  6.  DO test pump before using to be sure that the system is working properly.  

  7.  DO inspect and test system for proper operations at least every 3 months. 

© Copyright 2017 Zoeller

®

 Co. All rights reserved.

representative or other person to assume for us any other liability in connection 

with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  40211, 

Attention: Customer Support Department to obtain any needed repair or 

replacement of part(s) or additional information pertaining to our warranty.

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, 

CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED 

OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR 

A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED 

TO THE DURATION OF THE EXPRESSED WARRANTY.

Some states do not allow limitations on the duration of an implied warranty, so 

the above limitation may not apply to you. Some states do not allow the exclusion 

or limitation of incidental or consequential damages, so the above limitation or 

exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other rights 

which vary from state to state.

LIMITED WARRANTY

Manufacturer warrants, to the purchaser and subsequent owner during the warranty 

period, every new product to be free from defects in material and workmanship 

under normal use and service, when properly used and maintained, for a period 

of one year from date of purchase. Proof of purchase is required.   Parts that fail 

within the warranty period that inspections determine to be defective in material 

or workmanship will be repaired, replaced or remanufactured at Manufacturer's 

option, provided however, that by so doing we will not be obligated to replace 

an entire assembly, the entire mechanism or the complete unit.  No allowance 

will be made for shipping charges, damages, labor or other charges that may 

occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any material 

or product that has been disassembled without prior approval of Manufacturer, 

subjected to misuse, misapplication, neglect, alteration, accident or uncontrollable 

act of nature; that has not been installed, operated or maintained in accordance 

with Manufacturer's installation instructions; that has been exposed to outside 

substances including but not limited to the following:  sand, gravel, cement, mud, 

tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other 

abrasive or corrosive substances, wash towels or feminine sanitary products, 

etc. in all pumping applications.  The warranty set out in the paragraph above is 

in lieu of all other warranties expressed or implied; and we do not authorize any 

In those instances where damages are incurred as a result of an alleged pump failure, 

the Homeowner must retain possession of the pump for investigation purposes.

Содержание 118

Страница 1: ...ns chemicals known to the state of California to cause cancer and birth defects or other reproductive harm NOTICE TO INSTALLER Instructions must remain with installation FM2820 0517 Supersedes 0815 MODEL 118 FLOOD KIT PREINSTALLATION CHECKLIST 1 Inspect your unit Occasionally products are damaged during shipment If the unit is damaged contact your dealer before using DO NOT remove the test plug or...

Страница 2: ... theabovelimitationmaynotapplytoyou Somestatesdonotallowtheexclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state LIMITED WARRANTY Manufacturerwarrants tothepurchaserandsubsequentownerduringthewarranty period every new pro...

Страница 3: ...13436 SK2970A SK2970 COMPONENTS ATTACH ROPETO HANDLE ROPE SUPPLIED BY OTHERS Securing Rope to Handle HOSE DISCHARGE KIT CRAWL SPACE BASIN COVER MOUNTING BRACKET PUMP S S HANDLE CLEVIS PIN HAIRPIN COTTER PIN SPACER FLATWASHER HOSE CLAMP HOOK AND LOOP STRAP SERVICE PARTS Hose Discharge Kit 1010 0117 Pump M76 76 0016 Copyright 2017 Zoeller Co All rights reserved ...

Страница 4: ...al overload open Contact a Zoeller Authorized Service Station Bound impeller Shorted motor or wiring Damaged float Bound float assembly Check for debris around float B PUMP TRIPS OVERLOAD OR BLOWS FUSE Incorrect voltage Have a qualified electrician check circuit Bound impeller Contact a Zoeller Authorized Service Station Shorted motor C PUMP STARTS AND STOPS TOO OFTEN Short cycling Check for debri...

Страница 5: ...0S MODELO 118 JUEGO CONTRA INUNDACIONES LISTA DE VERIFICACIÓN DE PRE INSTALACIÓN 1 Inspeccione todos materiales Ocasionalmente los productos se dañan durante el envío Si la unidad está dañada comuníquese con su vendedor antes de usarla NO quite los tapones de prueba de la bomba 2 Lea cuidadosamente toda la literatura provista para familiarizarse con los detalles específicos relacionados con la ins...

Страница 6: ...ARA UN FIN PARTICULAR Y DE COMERCIALIZACIÓN SE LIMITARÁ A LA DURACIÓN DE LA GARANTÍA EXPRESA Algunosestadosnopermitenlimitacionesenladuracióndeunagarantíaimplícita de forma que la limitación anterior podría no aplicar a usted Algunos estados no permiten la exclusión o limitación de daños incidentales o emergentes de forma que la limitación o exclusión anterior podría no aplicar a usted Esta garant...

Страница 7: ...SOGA CON LA MANIJA LA SOGA ES SUMINISTRADA POR TERCEROS Asegure soga a la manija CORREA DE BUCLE Y GANCHO CONTENEDOR DE CÁMARA SANITARIA CUBIERTA SOPORTE DE MONTAJE BOMBA MANIJA DE ACERO INOXIDABLE PASADOR DE GRILLETE HORQUILLA SEPARADOR ARANDELA PLANA ABRAZADERA DE MANGUERA PIEZAS DE SERVICIO Juego de descarga de mangueras 1010 0117 Bomba M76 76 0016 Copyright 2017 Zoeller Co Todos los derechos r...

Страница 8: ...ascado Revise si hay escombros alrededor del flotador B EL MOTOR SE SOBRECALIENTA Y ACTIVA LA PROTECCIÓN CONTRA SOBRECARGA O DESCONECTA EL FUSIBLE Voltaje incorrecto Pídale a un electricista calificado que revise el circuito Impulsor atascado Comuníquese con un centro de servicio autorizado de Zoeller Motor en corto C LA BOMBA SE ENCIENDA Y SE APAGA MUY A MENUDO Ciclos muy cortos Revisesihayescomb...

Страница 9: ...AVANT L INSTALLATION 1 Inspecter tout matériaux De temps en temps la pompe est endommagée en cours d expédition Si la pompe est endommagée contacter le distributeur avant de l utiliser NE PAS enlever les bouchons test du la pompe 2 Il faut lire attentivement tous les documents fournis pour se familiariser avec les détails spécifiques de l installation et de l utilisation Il faut conserver ces docu...

Страница 10: ...FIQUE OU DE COMMERCIALITÉ EST LIMITÉE À LA DURÉE DE LA GARANTIE EXPRESSE Certaines provinces ne permettent pas les limitations de la durée de la garantie implicite et il est possible que cette limitation ne s applique pas Certaines provinces ne permettent pas l exclusion ou la limitation des dégâts secondaires ou indirects et il est possible que cette limitation ou exclusion ne s applique pas Cett...

Страница 11: ...IGNÉE CORDE FOURNIE PAR D AUTRES Fixer la corde à la poignée KIT DETUYAU D ÉVACUATION VIDE SANITAIRES DE LA CUVE COUVERCLE SUPPORT DE FIXATION POMPE POIGNÉE EN ACIER INOXYDABLE GOUPILLE DE BLOCAGE GOUPILLE EN ÉPINGLE À CHEVEUX ENTRETOISE RONDELLE PLATE COLLIER DU FLEXIBLE CROCHET ET SANGLE POUR BOUCLE PIECES D ENTRETIEN Kit de tuyau d évacuation 1010 0117 Pompe M76 76 0016 Copyright 2017 Zoeller C...

Страница 12: ...Flotteur endommagé Flotteur bloqué Rechercher des débris autour du flotteur B LE MOTEUR SURCHAUFFE ET DÉCLENCHE LE DISJONCTEUR OU LA SÉCURITÉ THERMIQUE Mauvaise tension Demander à un électricien qualifié de vérifier le circuit Impulseur engorgé Contacter un Centre d entretien autorisé Zoeller Moteur en court circuit C LA POMPE SE MET EN MARCHE ET S ARRÊTE TROP FRÉQUEM MENT Cycle court Rechercher d...