3
© Copyright 2020 Zoeller
®
Co. All rights reserved.
1. Read all instructions before beginning installation.
2. Be certain that basin is on a firm level surface.
3. Do not use an automatic plumbing vent device.
4. Do not over-torque lid attachment screws.
5. Always use a check valve on the discharge line.
6. Test operation of pump per STEP 6.
Ten Helpful Hints For Easy Installation
Performance Characteristics
7. Always provide some means to disconnect basin from plumbing
for maintenance purposes.
8. Run unit at least once a month to verify proper operation.
9. The model number and date code can be found on the lid warning
label.
10. Plug pump into a properly grounded GFCI receptacle.
009898
1. DO read all installation material included with the pump.
2. DO inspect unit for any visible damage caused by shipping.
Contact dealer if unit appears to be damaged.
3. DO clean all debris from the basin and pump.
4. DO always disconnect pump from power source before handling.
DO always connect to a separately protected and properly
grounded ground fault protected circuit. DO NOT ever cut, splice
or damage power cord. DO NOT carry or lift pump by its power
cord. DO NOT use an extension cord.
Do’s And Don't’s For Installing A Unit
5. DO NOT use a discharge pipe smaller than the pump discharge
size.
6. DO test pump immediately after installation to be sure that the
system is working properly.
7. DO review all applicable local and national codes and verify that
the installation conforms to each of them.
8. DO NOT install unit in the ground.
20
10
0
GALLONS
LITERS
0
5
50
40
30
80
160
FLOW PER MINUTE
105/106/
80
60
70
240
131
Meters
PUMP PERFORMANCE CURVE
104/105/106/110/115/120/131
4
TOT
AL
DYNAMIC HEAD
2
10
15
6
20
FEET
METERS
25
20
6.1
Shut-off Head:
15
4.6
10
3.0
5
1.5
Feet
MODELS
Liters
273
231
170
19.25 ft. (5.9m)
--
19
34
43
--
72
95
25
23 ft. (7.0m)
45
129
163
61
72
Gal.
104
Liters
Gal.
Liters
Gal.
131
105/106
110/115/120
110/115/120
104
18 ft. (5.5m)
38
14
30
144
53
114
--
--