INLET

TAIL PIPE

TRAP

FLANGED TAIL PIPE

(SEE NOTE)

CORD SEAL OPENING

DISCHARGE

VENT

X

4 1/2"

TRAP DISCHARGE PARTIALLY

VISIBLE THROUGH THE CORD

SEAL OPENING.

4"

TRAP DETAIL

TAIL PIPE

TAILPIPE

LENGTH

DIMENSION MEASURED

IN STEP 1.

  STEP 4 

Internal Trap Installation Only

  4.1) 

Cut the tailpipe to the dimension determined in Figure 4.1.

 

  4.2) 

Install the sink drain components to the lid as shown in Figure 4.2.

 

  4.3) 

Orient the lid assembly as shown in Figure 4.3 and secure the trap components.  

   

(HAND TIGHTEN the assembly to the lid at this time.  Adjustment will be required in Step 5.)

 

Note:  To ensure a proper water seal, the extension must be installed as shown in the “trap detail”. 

 

INTERNAL TRAP COMPONENTS SUPPLIED BY OTHERS.

Figure 4.1

SK2004

Figure 4.3

Figure 4.2

Содержание 104 Series

Страница 1: ...er GFCI inaccordancewithnational electrical code and local codes 6 Installation and checking of electrical circuits and hardware should only be performed by a qualified licensed electrician 7 Risk of electric shock These pumps have not been investigated for use in swimming pool areas 8 Prop65 Warning for California residents Cancer and Reproductive Harm www P65Warning ca gov 1 Check to be sure you...

Страница 2: ...you specific legal rights and you may also have other rights which vary from state to state Limited Warranty ELECTRICAL PRECAUTIONS Before servicing a pump always shut off the main power breaker and then unplug the pump making sure you are not standing in water and wearing insulated protective sole shoes Under flooded conditions contact your local electric company or a qualified licensed electrici...

Страница 3: ...m the basin and pump 4 DO always disconnect pump from power source before handling DO always connect to a separately protected and properly grounded ground fault protected circuit DO NOT ever cut splice or damage power cord DO NOT carry or lift pump by its power cord DO NOT use an extension cord Do s And Don t s For Installing A Unit 5 DO NOT use a discharge pipe smaller than the pump discharge si...

Страница 4: ...de Standard IMPORTANT Check local and state codes before using the internal trap option 1 1 Figure 1 1A and 1 1B are typical configurations for installation of the drain systems The actual configuration will vary depending on your cabinet and sink configuration NOTE If installing the internal trap record the x dimension it will be required in Step 4 INTERNAL TRAP COMPONENTS SUPPLIED BY OTHERS Figu...

Страница 5: ...DIRECTED TOWARD THE FLOAT Water stream will be visible from this hole during pump run periods IMPORTANT DISCHARGE PIPE PUMP DISCHARGE WEEP HOLE SK2002 STEP 3 Installation of the Gasket 3 1 Install the gasket into the gasket seat at the top of the basin refer to Figure 3 1 for details Figure 3 1 SK2972 SEAL DETAIL BASIN SEAL ENSURE NOTCHES LINE UP ...

Страница 6: ...llation Only 4 1 Cut the tailpipe to the dimension determined in Figure 4 1 4 2 Install the sink drain components to the lid as shown in Figure 4 2 4 3 Orient the lid assembly as shown in Figure 4 3 and secure the trap components HAND TIGHTEN the assembly to the lid at this time Adjustment will be required in Step 5 Note To ensure a proper water seal the extension must be installed as shown in the...

Страница 7: ...on shown in Figure 5 1 5 2 Install the lid components as shown in Figure 5 2 NOTE Pull excess cordage through the opening and install the cord seal as shown in Figure 5 3A Insure o ring is in the cap before installation 5 3 Place the basin assembly in its final position and complete plumbing Secure all connections shown in 5 3A or 5 3B STEP 6 Initial Testing of Drain Basin System 6 1 Plug the cord...

Страница 8: ...8 115V 1 N A N A N A N A N A M98 007921 N A 1 N A N A N A N A N A M98 35 cord 150116 N A Replacement pump M72 115V 1 N A N A N A N A N A N A M72 72 0001 Replacement pump M63 115V 1 N A M63 63 0009 N A N A N A N A N A 2 Basin Tank 1 013017 013017 013017 013017 013017 013017 013017 3 Discharge Pipe 1 013732 013732 013732 013732 013732 014759 013732 4 Basin Cover 1 013018 013018 013018 013018 013018 ...

Отзывы: