background image

2

© Copyright 2020 Zoeller

®

 Co. All rights reserved.

Manufacturer warrants, to the purchaser and subsequent owner 

during the warranty period, every new product to be free from defects 

in material and workmanship under normal use and service, when 

properly used and maintained, for THE PERIOD MENTIONED IN THE 

CHART  BELOW  FOR  THE  SPECIFIC  MODEL  PURCHASED,  from  the 

date of purchase. Proof of purchase is required. Parts that fail within 

the warranty period, that inspections determine to be defective in 

material or workmanship, will be repaired, replaced or remanufactured 

at Manufacturer's option, provided however, that by so doing we will 

not be obligated to replace an entire assembly, the entire mechanism 

or the complete unit. No allowance will be made for shipping charges, 

damages, labor or other charges that may occur due to product 

failure, repair or replacement. This warranty does not apply to and 

there shall be no warranty for any material or product that has been 

disassembled without prior approval of Manufacturer, subjected to 

misuse, misapplication, neglect, alteration, accident or act of nature; 

that has not been installed, operated or maintained in accordance 

with Manufacturer's installation instructions; that has been exposed 

to outside substances including but not limited to the following: sand, 

gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives (oil, 

gasoline, solvents, etc.), or other abrasive or corrosive substances, 

wash towels or feminine sanitary products, etc. in all pumping 

applications. The warranty set out in the paragraph above is in lieu 

of all other warranties expressed or implied; and we do not authorize 

any representative or other person to assume for us any other liability 

in connection with our products. Contact Manufacturer at, 3649 Cane 

Run  Road,  Louisville,  Kentucky  40211,  Attention:  Customer  Service 

Department to obtain any needed repair or replacement of part(s) or 

additional information pertaining to our warranty. 

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, 
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED 
OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR 
A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED 
TO THE DURATION OF THE EXPRESSED WARRANTY. 

Some  states do  not  allow  limitations  on  the  duration  of  an  implied 

warranty, so the above limitation may not apply to you. Some states 

do not allow the exclusion or limitation of incidental or consequential 

damages, so the above limitation or exclusion may not apply to you. 

This warranty gives you specific legal rights and you may also have 

other rights which vary from state to state.

Limited Warranty

 

 ELECTRICAL PRECAUTIONS-

 

Before servicing a pump, always shut off the main power breaker and then unplug the pump 

- making sure you are not standing in water and wearing insulated protective sole shoes. Under flooded conditions, contact your local 

electric company or a qualified licensed electrician for disconnecting electrical service prior to pump removal.

 Submersible pumps can become pressurized under normal operating conditions — allow 2-1/2 hours after disconnecting before 

attempting service.

CONDITION

A.    Pump will not start or run. 

 

B.   Motor overheats and trips 

overload or blows fuse.

C.   Pump starts and stops too often.

D.   Pump will not shut off. 

E.   Pump operates but delivers little 

or no water. 

F.  Drop in head and/or capacity after 

a period of use. 

G.  If tank or fittings leak.

If the above checklist does not uncover the problem, consult the factory. do you attempt to service or otherwise disassemble pump. Service must 

be performed by Zoeller autorized Service and warranty centers. Go to www.zoellerpump.com to find the authorized service center in your area.   

Service Checklist

COMMON CAUSES

Check fuse, low voltage, overload open, open or incorrect wiring, open switch, impeller or seal bound 

mechanically, defective capacitor or relay when used, motor or wiring shorted. Float assembly held 

down. Switch defective, damaged, or out of adjustment.

Incorrect voltage, negative head (discharge open lower than normal) impeller or seal bound mechanically, 
defective capacitor or relay, motor shorted.

Float too tight on rod, check valve stuck, or none installed in long distance line, overload open, switch

defective.

Debris under float assembly, float or float rod bound by basin sides or other, switch defective, damaged or out of 

adjustment.

Check strainer housing, discharge pipe, or if check valve is used, the vent hole must be clear. Discharge 
head exceeds pump capacity. Low or incorrect voltage. Incorrect motor rotation. Capacitor defective. 

Incoming water containing air or causing air to enter pumping chamber.

Increased pipe friction, clogged line or check valve. Abrasive material and adverse chemicals could 
possibly deteriorate impeller and pump housing. Check line. Remove base and inspect.

Carefully tighten pipe joints (use pipe dope) and screws. Check gasket location, tighten lid evenly. Do 
not over tighten fittings or screws.

In instances where property damages are incurred as a result of an alleged product failure, the property 

owner must retain possession of the product for investigation purpose.  

Drain Pump Model

104

105

106

110

115

120

131

Pump Model

M72

M53

M63

M55

M57

M59

M98

Warranty

2 year

3 year

5 year

1 year

3 year

1 year

3 year

Содержание 104 Series

Страница 1: ...er GFCI inaccordancewithnational electrical code and local codes 6 Installation and checking of electrical circuits and hardware should only be performed by a qualified licensed electrician 7 Risk of electric shock These pumps have not been investigated for use in swimming pool areas 8 Prop65 Warning for California residents Cancer and Reproductive Harm www P65Warning ca gov 1 Check to be sure you...

Страница 2: ...you specific legal rights and you may also have other rights which vary from state to state Limited Warranty ELECTRICAL PRECAUTIONS Before servicing a pump always shut off the main power breaker and then unplug the pump making sure you are not standing in water and wearing insulated protective sole shoes Under flooded conditions contact your local electric company or a qualified licensed electrici...

Страница 3: ...m the basin and pump 4 DO always disconnect pump from power source before handling DO always connect to a separately protected and properly grounded ground fault protected circuit DO NOT ever cut splice or damage power cord DO NOT carry or lift pump by its power cord DO NOT use an extension cord Do s And Don t s For Installing A Unit 5 DO NOT use a discharge pipe smaller than the pump discharge si...

Страница 4: ...de Standard IMPORTANT Check local and state codes before using the internal trap option 1 1 Figure 1 1A and 1 1B are typical configurations for installation of the drain systems The actual configuration will vary depending on your cabinet and sink configuration NOTE If installing the internal trap record the x dimension it will be required in Step 4 INTERNAL TRAP COMPONENTS SUPPLIED BY OTHERS Figu...

Страница 5: ...DIRECTED TOWARD THE FLOAT Water stream will be visible from this hole during pump run periods IMPORTANT DISCHARGE PIPE PUMP DISCHARGE WEEP HOLE SK2002 STEP 3 Installation of the Gasket 3 1 Install the gasket into the gasket seat at the top of the basin refer to Figure 3 1 for details Figure 3 1 SK2972 SEAL DETAIL BASIN SEAL ENSURE NOTCHES LINE UP ...

Страница 6: ...llation Only 4 1 Cut the tailpipe to the dimension determined in Figure 4 1 4 2 Install the sink drain components to the lid as shown in Figure 4 2 4 3 Orient the lid assembly as shown in Figure 4 3 and secure the trap components HAND TIGHTEN the assembly to the lid at this time Adjustment will be required in Step 5 Note To ensure a proper water seal the extension must be installed as shown in the...

Страница 7: ...on shown in Figure 5 1 5 2 Install the lid components as shown in Figure 5 2 NOTE Pull excess cordage through the opening and install the cord seal as shown in Figure 5 3A Insure o ring is in the cap before installation 5 3 Place the basin assembly in its final position and complete plumbing Secure all connections shown in 5 3A or 5 3B STEP 6 Initial Testing of Drain Basin System 6 1 Plug the cord...

Страница 8: ...8 115V 1 N A N A N A N A N A M98 007921 N A 1 N A N A N A N A N A M98 35 cord 150116 N A Replacement pump M72 115V 1 N A N A N A N A N A N A M72 72 0001 Replacement pump M63 115V 1 N A M63 63 0009 N A N A N A N A N A 2 Basin Tank 1 013017 013017 013017 013017 013017 013017 013017 3 Discharge Pipe 1 013732 013732 013732 013732 013732 014759 013732 4 Basin Cover 1 013018 013018 013018 013018 013018 ...

Отзывы: