1.2 I  Technical specifications

Standards

Defrost

Z200

M2

M3

M4

M5

MD2

MD3

MD4

MD5

PI20

PI2021 PI2031 PI2041 PI2051 PI2021D PI2031D PI2041D PI2051D

Operating temperature range

air

5 to 32°C

- 5 to 32°C

water

up to 32°C

Operating power*

kW

4.5

6.4

7.9

9.7

4.8

7

8.1

10.1

Power supply

220-240 V / 50Hz

Defrosting by forced air circulation

X

X

X

X

Defrosting by cycle inversion

X

X

X

X

Acceptable variation in voltage

-10%, +7% (during operation)

Nominal absorbed intensity

A

4.5

6.3

7.9

11.2

4.5

6.3

7.9

11.2

Maximum absorbed intensity

A

5.2

7.6

10.2

13.4

5.2

7.6

10.2

13.4

Minimum cable section**

mm²

3x2,5

3G2,5

Proof pressure

bar

6

Service pressure

bar

1.5

Max. Discharge/Suction Pressure

bar

42/1.2

Max. high-pressure/low pressure 

side pressure

bar

42/1.2

Head loss

mCE

1

1.5

1

1.5

Minimum optimum water flow rate

m³/h

4

Maximum water flow 

m³/h

10

Refrigerant type

R32

Refrigerant charge

kg

0.68

0.8

0.9

1.1

0.68

0.8

0.9

1.1

Weight

kg

40

45

50

53

40

45

50

53

The appliances have an Ingress Protection (IP) rating of IPX4 or better. Please refer to the marking indicating the IP-rating 

on your particular product.

* Performance: air 15 °C / water 26 °C / humid. 70%.

** Values provided for information purposes for a maximum length of 20 metres (calculation base: NFC15-100), must be checked and adapted to the 

installation conditions and standards of the installation country.

Содержание Z200

Страница 1: ...H0548500_REVF 2021 02 More documents on www zodiac com Z200 Defrost Z200 PI20 Defrost PI20 Instructions for installation and use English Heat pump Translation of the original instructions in French EN...

Страница 2: ...sed for any purpose other than that for which it was designed This appliance is not intended for use by individuals including children with impaired physical sensorial or mental abilities or persons l...

Страница 3: ...on the appliance with wet hands or if the appliance is wet Before connecting the appliance to the source of supply ensure that the terminal block or supply socket to which the appliance will be conne...

Страница 4: ...designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated s...

Страница 5: ...rinciple 12 3 2 User interface presentation 12 3 3 I Operating 13 3 4 I User functions 14 Maintenance 15 4 1 I Winterizing 15 4 2 I Maintenance 15 Troubleshooting 18 5 1 I Device behaviour 18 5 2 I Er...

Страница 6: ...A Z200 PI20 B Joint x2 C Screw in connector x2 D 40 adaptation x2 E 50 reduction x2 F Condensation evacuation kit 15 G Winterizing cap x2 H Winterizing cover Heating priority I Remote control J PAC N...

Страница 7: ...cable section mm 3x2 5 3G2 5 Proof pressure bar 6 Service pressure bar 1 5 Max Discharge Suction Pressure bar 42 1 2 Max high pressure low pressure side pressure bar 42 1 2 Head loss mCE 1 1 5 1 1 5...

Страница 8: ...on valve and user interface Ventilator Technical access door Pool water intake Pool water output Evaporator Grommet for heating priority cable run Location for drilling for remote control cable run de...

Страница 9: ...und The device must not be installed In a closed and unventilated room In a location subject to high winds With the blowing towards a permanent or temporary obstacle window wall hedge awning etc less...

Страница 10: ...o make it easier to work on the device water entry valve by pass valve water exit valve water entry adjustment valve optional water exit adjustment valve optional water treatment minimum distance To e...

Страница 11: ...hnical specifications with a 30 mA dedicated differential circuit breaker circuit breaker or switch at the head of the line The electricity supply must correspond to the voltage indicated on the devic...

Страница 12: ...p power contactor coil filtration timer power contactor tripolar or bipolar for the filtration system pump motor separate cable for the heating priority function heat pump terminal see wiring diagram...

Страница 13: ...ing range sufficient to heat Cover the basin with a sheet bubble canopy canvas etc to prevent heat loss Take advantage of a period with mild outdoor temperatures on average 10 C at night your heat pum...

Страница 14: ...adually so that the filter pressure is increased by 150g 0 150 bars Open valves A C and D fully then valve E by half the air which has built up in the heat pump condenser and the filtration circuit wi...

Страница 15: ...the setpoint temperature is displayed fixed To read the water temperature it is imperative that the filtration is in operation and that the water flow indicator is fixed 3 4 2 Locking unlocking the k...

Страница 16: ...nd other personnel working in the surrounding area must be made aware of the work carried out Work conducted in enclosed areas must be avoided Check for the presence of refrigerant The area must be an...

Страница 17: ...nd intensity for the equipment being used Typically safe components are the only types on which work can be carried out in the presence of a flammable atmosphere when live The test appliance must fall...

Страница 18: ...ll a manifold in order to be able to remove the refrigerant from various locations within the system 6 Make sure that the cylinder is located on the scales before starting recovery operations 7 Start...

Страница 19: ...your heat pump cannot manage to deice its evaporator it will stop itself this means that the outdoor temperature is too low below 5 C for standard models 5 C for Defrost models The device is not worki...

Страница 20: ...temperature too high 32 C maximum Wait until the temperature falls Flow controller blocked Check the flow controller Water condenser scaled up or blocked Clean the water condenser Outside temperature...

Страница 21: ...p relay Earth KM4 Complementary relay C1 Compressor condenser M1 Compressor C2 Ventilator condenser M2 Ventilator CD Flow controller SD1 Water temperature sensor E1 High pressure switch SD2 Air temper...

Страница 22: ...KM4 Complementary relay C1 Compressor condenser M1 Compressor C2 Ventilator condenser M2 Ventilator CD Flow controller SD1 Water temperature sensor HP High pressure switch SD2 Air temperature sensor...

Страница 23: ...rty of their respective owners Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Pour plus d informations enregistrement produit et support client For more in...

Отзывы: