2.2 I Hydraulic connections
•
The device will be connected with a Ø40 or Ø50 PVC pipe, using the connectors supplied (see § “1.1 I Description”),
to the pool's filtration circuit, after the filter and before the water treatment.
•
Respect the direction of hydraulic connection (
= input and
= output).
•
A by-pass must be installed to make it easier to work on the device.
:
water entry valve
: by-pass valve
:
water exit valve
:
water entry
adjustment valve
(optional)
:
water exit
adjustment valve
(optional)
: water treatment
* minimum distance
•
To evacuate the condensation, fit a Ø15 pipe on the grooved elbow to be mounted under the device base (supplied
according to model, see § “1.1 I Description”).
Tip: condensation drainage
Caution, several litres of water must be drained from your device each day. We strongly recommend
connecting the drainage to the sewers