2.2 Installing the TRi pH or TRi PRO module

•  

Turn  off  your  Zodiac  TRi  salt  chlorina

-

tor and then filtration by cutting off the 
main  electricity  supply  in  order  to  iso

-

late the installation.

•  

Close  the  isolating  valves  in  the  pipe

-

work.

•  

Remove the silver cover by pressing the 
sides  and  raising  it,  then  unscrew  the 
four screws attaching the original (emp

-

ty) lower module to the main unit.

•  

Remove the empty module and offer up 
the TRi pH or TRi PRO module. 

•  

Connect  the  ribbon  cable  from  the  TRi 
pH or TRi PRO to the connector on the 
TRi power pack. 

•  

Put the TRi pH or TRi PRO module in po

-

sition,  replace  the  four  screws  and  re

-

place the silver cover.

•  

Do not reconnect the electricity supply until the TRi pH or TRi PRO module, the sensor-holding POD and the pH 
minus injection pipe have been installed (see § 2.3.3).

•  

Always wait 2 minutes, particularly when performing any technical work, between disconnecting the TRi from 
the mains electricity supply and connecting the TRi pH or TRi PRO module.

2.3 Installing the POD

The sensor-holding POD is a single assembly including the flow rate detector (used by your TRi chlorinator, see § 2.3.2), 
the pH and ACL sensors and pH minus injection.

•  

The TRi unit bypass valves must always be open.

•  

The sensor-holding POD must always be positioned on a horizontal pipe so that the sensors are vertical.

•  

The POD must be the first unit fitted after the pool filter.

•  

If the pool is fitted with a heating system (heat pump, heat exchanger, electric heater, etc.), the POD must be 
installed before it (to take readings on unheated water).

•  

We recommend positioning the POD more than 20 cm from an elbow in the pipe.

•  

The sensor cables must not be positioned near high voltage mains electricity cables.

pH sensor

Flow switch

Water circulation direction

pH minus injection

ACL sensor

A badly-installed sensor may give false readings and cause inappropriate operation of the TRi unit. Neither the 
manufacturer nor the unit shall be liable in this event.

Содержание TRi pH Module

Страница 1: ...H00412500 A 2013 02 Instructions for installation and use English More languages on www zodiac poolcare com ...

Страница 2: ...t is important that this equipment is operated by competent and qualified both physically and mentally people that have previously received the instructions for use by reading this booklet Any person not meet ing these criteria should not go near the equipment to avoid the risk of being exposed to dangerous com ponents If the equipment malfunctions do not attempt to repair the equipment yourself c...

Страница 3: ...aring the pool water balance 4 2 2 Installing the TRi pH or TRi PRO module 5 2 3 Installing the POD 5 3 Use 7 3 1 Activating the module 7 3 2 Display 7 3 3 Calibrating the sensor s 8 3 4 Adjusting the set point s 8 3 5 Setting the pool volume 9 3 6 Peristaltic pump 9 4 Maintenance 10 4 1 Cleaning the sensor s 10 4 2 Winterizing 10 5 Troubleshooting 10 6 Product registration 11 ...

Страница 4: ...clip PTFE tape and stoppers suction injection hose 5 meters Hole saw 22 mm 1 2 2 TRi PRO module TRi PRO module POD pH sensor ACL sensor Hole saw 22 mm Accessory bag 2 sensor holders counterweight securing clip PTFE tape and stoppers suction injection hose 5 meters Buffer solution pH 7 5 Buffer solution 700 mV 1 3 Technical specifications TRi pH module TRi PRO module Supply voltage Low voltage conn...

Страница 5: ...ipment Ensuring the water balance of the pool is correct from the start will reduce the likelihood of encountering problems in the first days operation or during the season using the pool Even if it is an automatic control system it is essential to analyze the water regularly to check the water balance parameters Unit Recommended values To increase To decrease Test frequency during season pH 7 2 t...

Страница 6: ...chnical work between disconnecting the TRi from the mains electricity supply and connecting the TRi pH or TRi PRO module 2 3 Installing the POD The sensor holding POD is a single assembly including the flow rate detector used by your TRi chlorinator see 2 3 2 the pH and ACL sensors and pH minus injection The TRi unit bypass valves must always be open The sensor holding POD must always be positione...

Страница 7: ... Position the upper part of the POD with its various components in the direction indicated by the foolproof locating notch and tighten the locking ring firmly hand tighten only 2 3 1 Installing the pH and ACL sensors Take the sensor holder s and put 10 to 12 turns of PTFE tape around its main thread Screw the sensor holder into its seat on the POD Carefully unscrew the protective bottle from the s...

Страница 8: ...mp to the injection non return valve located on the POD Attach the pipe to the threaded connector on the peristaltic pump outlet Attach the other end of the pipe to the injection non return valve b Installing the intake pipe container peristaltic pump Cut a suitable length of pipe from the coil supplied to connect the container of pH minus to the peristaltic pump Attach the pipe to the threaded co...

Страница 9: ...er and shake them to remove excess water Do not touch or wipe the glass bulb at the end of the sensors Put the pH sensor into a sample of the pH7 5 buffer solution supplied Put the ACL sensor into a sample of the 700 mV buffer solution supplied Leave the sensors immersed for about 1 minute to obtain a reliable measurement Press then use the or keys to display CALIB PH or CALIB PH ACL then press Us...

Страница 10: ...ls over 110 m These values are for guidance only the choice may vary according to the conditions of use When the volume of the pool is at the limit between 2 levels it is better to use the higher level However we recommend not over sizing the choice of level to avoid using too much pH minus A dose of pH minus is injected into the pool every 2 hours when the filtration and TRi chlorinator systems a...

Страница 11: ...ed solution of hydrochloric acid for a few minutes wear the necessary safety equipment Rinse thoroughly with clean water Calibrate the sensor again see 3 3 This acidic cleaning solution can be bought from your reseller or you can make it up yourself by mixing 1 volume of acid with 9 volumes of clean water in a suitable container ALWAYS ADD ACID TO WATER NEVER THE OTHER WAY AROUND Always clean the ...

Страница 12: ...Reduce the ACL set point Ensure the water is not too mineral bore hole water prohibited ACL ERROR ACL adjustment has allowed chlorine pro duction for a total of more than 30 hours without reaching the ACL set point Check the pH in the pool Clean and calibrate the sensors Replace the buffer solutions if necessary Replace the sensors Use the boost mode if necessary The chlorinator has not produced c...

Страница 13: ... 61558 2 6 1997 Safety of power transformers power supply units reactors and similar products Particular requirements for safety isolating transformers and power supply units incorporating safety isolating transformers AS NZ 3136 2001 Approval and Test Specification Electrical Equipment for spa baths and spa and swimming pools Incorporating IEC 60065 Audio video and similar electronic equipment sa...

Страница 14: ...lease contact your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer www zodiac poolcare com Zodiac Pool Care Europe BP 90023 49180 St Barthélémy d Anjou cedex S A S U au capital de 517 200 SIREN 395 068 679 RCS PARIS ...