H0412500.A - EN - 2013-02
3
1. Information before installation
1.1 General delivery conditions
All equipment, even carriage and packaging paid, is shipped at the recipient's risk. If damaged caused during transport
is observed, the recipient should write appropriate comments on the delivery note provided by the carrier (and con
-
firmed in writing to the carrier by registered letter).
1.2 Contents
1.2.1 TRi pH module
TRi pH module
POD
pH sensor
Buffer solution pH 7.5
Accessory bag (sensor holder, counter securing
clip, PTFE tape and stoppers)
s injection hose
(5 meters)
Hole saw, 22 mm
1.2.2 TRi PRO module
TRi PRO module
POD
pH sensor
ACL sensor
Hole saw, 22 mm
Accessory bag (2 sensor holders, counter
securing clip, PTFE tape and stoppers)
s injection
hose (5 meters)
Buffer solution
pH 7.5
Buffer solution
700 mV
1.3 Technical specifications
TRi pH module
TRi PRO module
Supply voltage
Low voltage (connected to the TRi chlorinator)
Peristaltic pump flow rate
1.8 L/h
Maximum back pressure (injection)
1.5 bar
pH and ACL sensor type
combined, epoxy body Ø12mm (pH = blue / ACL = red)
pH and ACL sensor electrolyte
KCI polymer
pH and ACL sensor cable(s)
5 meters armored, BNC plug (pH = blue / ACL = red)
pH correction
acid (pH minus only)