background image

19

EN

❹ Maintenance

  

 4.1 I  Winterising

 

•  The frost protecti on functi on is only designed to protect the appliance and pipework during 

short periods of subzero temperatures. It acti vates the fi ltrati on pump and circulates water 

to prevent freezing inside the appliance. The frost protecti on functi on does not guarantee 

protecti on  during  extended  periods  of  subzero  temperatures  or  power  cuts.  In  these 

conditi ons, the pool must be completely winterised. If the pump freezes, it may cause severe 

damage and invalidate the warranty. 

•  To avoid damaging the appliance with condensati on, do not fully cover it.

• 

If the pump is positi oned below the water level, close the isolati on valves at sucti on and discharge.

• 

Drain the pump (using the 2 bleed screws) and the hydraulic circuit, following the swimming pool manufacturer's 

instructi ons.

• 

Remove the 2 bleed screws and keep them to reinstall them when the pump is put back into operati on.

• 

You are encouraged to disconnect the electrical power cable then unscrew the hydraulic connectors to store the 

pump in a dry place protected from frost.

• 

Store the pump in a dry environment at a temperature that varies as litt le as possible to prevent condensati on which 

would damage the pump.

  

 4.2 I  Servicing

•  It is recommended that the appliance undergo general servicing at least on a yearly basis 

to  ensure  proper  operati on,  maintain  performance  levels  and  potenti ally  prevent  certain 

failures. These operati ons must be carried out at the user's expense by a qualifi ed technician.

4.2.1 User maintenance

• 

Make sure that the pump and electrical compartment contain no foreign bodies.

• 

Clean the outside of the appliance, do not use solvent-based products.

• 

Clean the pre-fi lter strainer, the cover and the gasket regularly.

• 

Check that the pre-fi lter strainer is correctly in place, or it may prevent the cover from closing fully.

4.2.2 Maintenance to be carried out by a qualifi ed technician

• 

Check and confi rm that all metal components of the appliance are reliably connected to earth (grounded).

• 

Check that the electrical cables are correctly ti ghtened and connected and that the switch box is clean.

Содержание FloPro VS

Страница 1: ...0589800 B 2017 03 More documents on www zodiac poolcare com FloPro VS FR Instructions for installation and use English Filtration pump Translation of the original instructions in french EN PT ES DE NL...

Страница 2: ......

Страница 3: ...he direction of the appliance as this may damage the body and cause a re The power supply to the appliance must be protected by a dedicated 30 mA residual current device complying with the standards a...

Страница 4: ...ervicing 19 Troubleshooting 20 5 1 I Appliance behaviour 20 Before handling the appliance it is essential that you read this installation and user manual as well as the warnings and warranty booklet d...

Страница 5: ...3 EN Speci cations 1 1 I Description or A FloPro VS JEP with user interface AUT without user interface B 63 50 mm connectors x2 C Pump bases x2 D Cable gland x2 E Remote user interface kit...

Страница 6: ...Maximum pump ow m h 30 7 Pump ow rate at 8 metres of head m h 26 0 Maximum pump head mH O 21 5 bar 2 1 Pump operation from 600 to 3 450 rpm Settings in intervals of 10 rpm Number of programmable speed...

Страница 7: ...5 EN 1 4 I Performance curves Flow rate Manometric head...

Страница 8: ...nd motor to cool The pump must not be installed in an area subjected to splashing rain or exposed to direct sunlight more than 3 m above the water level near a heat source or source of ammable gas in...

Страница 9: ...installed above the water level Fit suction and discharge isolation valves if the pump is installed below the water level To help prevent di culty in priming install the suction pipe without high poi...

Страница 10: ...l only start when commanded to do so via its user interface or via an external controller for example AquaLink TRi or iQPUMP The appliance s electrical supply must be provided through a protection and...

Страница 11: ...low 4 green Do not cut the RS485 cable as this will prevent the user interface from being reconnected to the pump and will make it impossible to restore the factory settings The cable is xed to the pu...

Страница 12: ...ble as this will prevent the user interface from being reconnected to the pump and will make it impossible to restore the factory settings The cable is xed to the pump and cannot be removed or extende...

Страница 13: ...the correct length of cable for the extension and connect it to the RS485 terminal board then connect it inside the electrical compartment Fit the cover and the foam gasket in the position of the use...

Страница 14: ...the grommet on the base see procedure 2 4 2 Remote user interface In the case of connection to an AquaLink TRi external controller this function will be automatically proposed by the controller 2 5 I...

Страница 15: ...xed to the pump and cannot be removed or extended Never lay these low voltage cables in the same pipe as high voltage cables Theuserinterface wherepresent becomesinactiveifthepumpisconnectedtotheAquaL...

Страница 16: ...of the active speed Pump speed Pump on Symbol Description Menu access button Con rm a selection Pre set eStar speed button 1 750 rpm Sub menu back button Pre set speed buttons Rotational speed modi ca...

Страница 17: ...it is perfectly sealed Bleed any air present in the ltration circuit using the bleed normally present on the lter refer to the swimming pool lter s manual Check that there are no leaks on the hydrauli...

Страница 18: ...access the Timer programme the speed that you want to programme must be running eStar speed or speed No 2 Speed LED Clock display Timer active Pump on red yes Timer active Pump o green yes Timer inac...

Страница 19: ...e user interface has been idle for 2 minutes Light o screen not back lit Light on screen permanently back lit To choose the interface language English Spanish French German Italian or Dutch To choose...

Страница 20: ...50 rpm Then the priming cycle time from 1 to 5 minutes The user interface displays when the pump is in the priming cycle To set the pre de ned eStar speed known by default as 1 Filtration The pump mea...

Страница 21: ...he electrical power cable then unscrew the hydraulic connectors to store the pump in a dry place protected from frost Store the pump in a dry environment at a temperature that varies as little as poss...

Страница 22: ...s The turbine and the pump di user are blocked or worn replace The di user seal is worn replace Reverse motor rotation three phase models only Check the electrical connection at the pump terminals Low...

Страница 23: ...49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Trouvez plus d...

Отзывы: