SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS. READ AND FOLLOW ALL INSTRUCTIONS. SAVE
ALL INSTRUCTIONS.
CHEMICAL USE HAZARD
•
To avoid personal injury when working with pool chemicals, always wear rubber gloves and
eye protection and work in a well-ventilated area. Use caution when choosing a location to
open and use chemicals as they may damage any surface in which they come in contact.
•
The addition of certain chemicals can reduce the effectiveness of chlorine. Always make
sure that proper residual chlorine levels are maintained to avoid personal injury.
•
This product manufactures chlorine. Individuals with any type of chlorine sensitivity should
take the appropriate precautions to avoid injury or illness.
EQUIPMENT WATER PRESSURE HAZARD
•
Always turn pump off prior to installing or removing the Zodiac EZ SALT Chlorine Generating
Device cell. Your pump and filter system operates under pressure and the pressure must be
released before you begin work. Please see your pump and filter owner’s manual for further
instructions.
•
To avoid cell damage, water pressure in the cell must not exceed 200kPa (29psi).
WARNING Failure to heed the following warnings could cause damage to pool equipment or
personal injury.
•
The Zodiac EZ SALT Chlorine Generating Device for above ground pools must be installed
and operated as specified.
•
Scratching or bending plates in cell housing can reduce cell life.
•
Power to the EZ SALT Chlorine Generating Device should be turned off before unplugging
the cell connectors to prevent cell damage and low voltage sparks.
•
Keep the cell terminals protected with a light coating of silicone grease to allow for a positive
electric connection. Use of any other type of grease may damage the terminal seals and ‘o’
rings. Do not immerse these terminals in acid wash solution, and avoid accidental contact
with salt water.
•
Water above the temperature of 40ºC (104ºF) flowing through the cell can cause the plastic
cell to discolour.
•
Power
pack
must
not
be installed directly above any other heat source such as filter, pump
or heater. It must be at least 30 cm (12 inches) from the ground to allow free circulation of air
around it. It
must not
be installed in a closed box. If the power pack is to be installed on a
post, then it must be centrally positioned on a flat panel of suitable waterproof material at
least 30 cm (12 inches) wide and 30 cm (12 inches) high.
•
Check the cell frequently to prevent the accumulation of pool debris that for any reason may
have by-passed the pool filter.
•
Turn device off when backwashing filter.
•
Power supply to EZ SALT Chlorine Generating Device must be synchronized with pool pump
power source or automatic timer.
WARNING: The EZ SALT Chlorine Generating Device
must never be on without the pump being on.
WARNING
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or similarly qualified person in order to avoid any potential hazards
.
6