31
4.3.15. User interface energy saving mode
By default, the screen power saving mode is activated and an appliance which is unused goes into standby: an
animated production indicator is displayed and the measured values are not visible. To deactivate this mode:
• From the
Configuration/D15 ECO
mode, press
: “OFF” flashes.
•
Press
to switch to “ON”.
•
Press
to confirm.
4.3.16. "Bio": "Bio pool" mode for natural pools
The
"Bio"
mode is used to modify the pH and ORP setpoints and the related high and low alarms (see the values in the
table below) so they are best suited to natural pools.
« Bio pool »
mode
Threshold
Alarm
High (HI)
Low (LO)
pH
OFF (default)
7.0
7.8
> 8.5
< 6.5
ON
6.5
8.5
> 9.0
< 6.0
ORP (mV)
OFF (default)
600
850
> 855
< 600
ON
300
850
> 855
< 300
By default, this mode is disabled; to activate it:
• From the
Configuration/bio mode,
press
: "OFF" flashes.
•
Press
to activate it ("ON").
•
Press
to confirm.
4.3.17. Calibrating the temperature
• From the home screen, press
to access the temperature values (*).
•
Press
to enter the
Calibration
mode. The screen displays
(“Standard”).
•
Press
to select this mode. The value flashes.
•
Press
or
to change the value.
•
Press
to confirm.
Press
at this step to switch between a temperature display in degrees Celsius (°C) and degrees Fahrenheit
(°F).
4.3.18. Calibrating the salt concentration
• From the home screen, press twice on
to access the salinity values.
•
Press
to enter
Calibration
mode. The screen displays
(“Standard”).
•
Press
to select this mode. The value flashes.
•
Press
or
to change the value.
•
Press
to confirm.