5
1.2 I Technical specifications
eXPERT
7
12
21
30
40
Operating water temperature
5 - 40°C
Volume of treated water (m³)
(temperate climate, 8h/day filtration)
30
50
100
140
180
Nominal chlorine production
7 g/h
12 g/h
21 g/h
30 g/h
40 g/h
Nominal output current
3.5 A
6 A
3.5 A
6 A
6.5 A
Fuse (5x20 mm)
1 A T
2 A T
2 A T
3.15 A T
4 A T
Recommended salt level
(g/L)
5
5
4
4
4
Min-max: 4-10
Power supply voltage
230V
50-60 Hz
Electrical power
46 W
92 W
92 W
184 W
207 W
Protection rating
IP
X
5
Minimum flow rate required through
the cell (m³/h)
3
3
5
6
8
Maximum allowable pressure in the
cell
1 bar
Number of electrode plates
3
5
7
11
13
Cell connection
Ø63 mm (use Ø50mm PVC reducers for 50mm pipe)
Sensor type
Combined, glass body Ø12 mm
pH measurement range
0.0 - 9.9 pH
pH measurement accuracy
0.
0
1
Sensor tolerance
0-40°C, water speed ≤ 2 m/s
pH sensor calibration
Semi-automatic in 2 points (pH 4 and pH 7)
ORP measurement scale
0 - 999 mV
ORP measurement accuracy
1 mV
ORP sensor calibration
Semi-automatic at 1 point (470 mV)
Maximum counter pressure (injection
point)
1.5 bar
Peristaltic pump flow rate (pH)
1.5 L/h
Length of box-cell cable
1.5 m
Packaged net weight (kg)
9
11
13
15
17