background image

 

 
 
 

IMPORTANT

 

 

These installation instructions are an integral part of the product and must be given to the installer 

and kept by the user. 
 

The warnings and indications contained in the present handbook must be carefully read and 

understood as they provide important information relative to handling and operating safety. This 

handbook must therefore always be kept available for later consultation. 
 

Installation must be carried out in compliance with valid regulations and the manufacturer’s 
instructions by a qualified professional. 

 

The term «qualified professional» refers to a person possessing the technical knowledge associated 

with P.S.A. components and heating installations. 
 

An installation error could result in physical injury to persons or animals as well as mechanical 
damage for which the manufacturer may under no circumstances be held responsible. 

 

After having unpacked the heat pump, the content should be checked for possible damage. 

 
Before connecting the heat pump, ensure that the data provided by P.S.A. is compatible with the 

true installation conditions and does not exceed the maximum authorised limits for the product in 
question. 

 

Before beginning any installation, handling or repair work on the heat pump, always isolate the 

electrical power supply to the unit. 
 

In the case of a fault and/or operating error on the heat pump, the electrical power supply must be 
isolated and no attempt should be made to repair the fault. 

 
Repair work may only be carried out by an authorised technical assistance service using original 

spare parts only. Non-respect of the aforementioned clauses may have a negative influence on 
the operating safety of the heat pump. 

 
To guarantee the efficiency and correct operation of the heat pump, it is important to ensure it is 

regularly maintained in compliance with the instructions provided by P.S.A. 
 

In the case where a heat pump is sold or transferred to another user, always ensure that all technical 
documentation is sent with the equipment to be used by the new user or installer. 

 
This heat pump may only be used for the purpose for which it was designed: to heat a swimming 

pool; all other uses must be considered inappropriate, incorrect or even dangerous. 
 

All contractual or extra-contractual responsibilities of P.S.A. will be considered nil and void for any 
damage caused by installation or operating errors, or due to non-respect of the instructions 

provided by P.S.A. or valid installation standards for the equipment object of the present document. 

Содержание Edenpac 4D

Страница 1: ...Ed 04 2007 EDPAC045DFAB EDPAC057DFAB EDPAC067DFAA R f 1011475 02 Heat pump Instructions for installation and use F GB D NL E P I 4D 5D 6D All seasons F GB D NL E P I...

Страница 2: ...efore beginning any installation handling or repair work on the heat pump always isolate the electrical power supply to the unit In the case of a fault and or operating error on the heat pump the elec...

Страница 3: ...4 1 2 Edenpac D with double fan 4 2 Hydraulic connections 10 4 3 Electric connections 11 5 Regulator operation 12 5 1 Presentation 12 5 2 Setting the target temperature 13 6 Starting up 13 6 1 Check...

Страница 4: ...2 Voltage Prior to any operation check that the voltage on the name plate of the appliance corresponds to the mains voltage provided on site 1 3 Water treatment In order to use our appliances under th...

Страница 5: ...e switch Cased SCROLL compressor 11 Arched plate fin evaporator 12 Anti frost sensor 13 Fastening plates with silent blocks 14 Pool inlet water connection 40 49 male screw fastening 15 Packing gland a...

Страница 6: ...op and bottom panels with polypropylene grid 2 Motor fan unit 3 Access flap to digital regulator 3a Euro FK and pressure gauge water flow 3b measures the refrigerant pressure in the HP circuit and is...

Страница 7: ...ac 4 and 5 D Dimensions of the appliance with packaging in mm Weight of Edenpac 4 D with packaging 105 kg Weight of Edenpac 5 D with packaging 110 kg 1275 480 870 To be transported upright in its orig...

Страница 8: ...6 2 2 2 Edenpac 6 D...

Страница 9: ...panner 13 1 ratchet spanner 1 pliers 2 straps for handling Choose the appliance installation site according to the following criteria the appliance must be installed outdoors the clearance around the...

Страница 10: ...re are not water jets In the contrary case respect a minimum distance of 3 5 metres Attention Do not lift the appliance by picking it up at the front and or the water inlet outlet points Use 2 lifting...

Страница 11: ...crews 2 and 3 on the right side using a cross head screwdriver Slide the entire front panel forward and then down 4 1 2 Edenpac D with double fan Turn the 2 clips 1a and 1b in the front turn clockwise...

Страница 12: ...ater treatment device see diagrams below Hydraulic circuit test pressure 3 bars Hydraulic circuit operating pressure 1 5 bar Edenpac 4 and 5 D Average water flow 6 5 m3 h pressure drop 1 7 mCE 0 17 ba...

Страница 13: ...all be kept Remote failure light In order to indicate in a technical facility that the heat pump is failing terminals 0 and 4 provide a signal that can be connected to a light or an alarm 230 V Priori...

Страница 14: ...measures the temperature in the pool and compares it to the target temperature If the water temperature becomes or is lower than the target temperature the regulator unit authorises heating after a se...

Страница 15: ...4 5 10 9 4 21 7 6 6 4 6 13 3 4 53 7 9 7 2 Tair 7 C Twater 24 C Power restored Power drawn Current drawn Throughput Edenpac D KW KW A m3 h 4 11 5 3 35 17 3 6 4 5 12 9 3 78 7 6 4 6 15 1 4 12 7 5 7 2 Tai...

Страница 16: ...water leak that the appliance is stable with a level gauge and spirit level that the cables are correctly connected to their terminals Incorrectly tightened cables may cause overheating of terminals...

Страница 17: ...lay thermostat is decreased filtration is switched off or valve V2 or V4 closed 6 4 Troubleshooting Faults Message Designation Cause Remedy Reset Alarm Control sensor fault Sensor defective or disconn...

Страница 18: ...lt a PSA approved technician to check the sensor and operation of the defrost cycle Cut power supply or press the button if dtd starts blinking after stand by Ofr5 and switch the regulator on again by...

Страница 19: ...th the compressor switched off Check electrical connections and terminals retighten the supply cable terminals Check earth connections Check sealing of the cooling circuit on the EdenPAC 6D Do not use...

Страница 20: ...diagram of connection interface card To J11 and J12 To J6 and J14 Phase failure module 500W J1 36 input 12Vdc 37 output 100Hz 38 input FAN J2 39 input Phase 230Vac 40 input Neutral 230Vac J3 41 outpu...

Страница 21: ...19 9 2 Electrical diagram EdenPAC D single phase IMPORTANT Elimination or shunting of one of the safety or remote control devices automatically cancels the GUARANTEE...

Страница 22: ...20 9 3 Electrical diagrams EdenPAC D three phase IMPORTANT Elimination or shunting of one of the safety or remote control devices automatically cancels the GUARANTEE...

Страница 23: ...n or shunting of one of the safety or remote control devices automatically cancels the GUARANTEE With an aim to improving its products PSA reserves the right to modify the characteristics without prio...

Страница 24: ...e eliminated or neutralised Your appliance is reaching the end of its working life You would like to get rid of it or replace it Please do not throw it into the dustbin or into your local council s se...

Страница 25: ...must be carried out with total respect of valid safety regulations and acceptable professional practice recuperation of refrigerant nitrogen brazing etc All brazing work must be carried out by a qual...

Страница 26: ...yst mes de chauffage et de d shumidification de piscines En s appuyant sur le savoir faire technologique et l exp rience de PSA Zodiac vous apporte la garantie d appareils de tr s haut niveau tant dan...

Страница 27: ...hank you for trusting us and enjoy your bath at 28 C Please take a little time to fill in this guarantee form with your pool adviser Your details may be treated according to the law Informatique et ci...

Страница 28: ...n de s rie Type and serial number Utilisateur Owner Installateur installer Station service agr e PSA Technical support Garantie guaranty Date de livraison Delivery date Date de mise en route Date of...

Отзывы: