1. Package content

Check that your appliance has not been damaged during transport (shocks, broken parts, etc.). If you find any problems do 

not hesitate to contact 

Z

odiac® before using the product.

Diag Box

 

(x1)

Adaptor organiser (x1)

Adaptors (x6)

2. Diag Box operating principle (Quick Test and Full Test)

The Diag Box is a tool which has been specially designed to help professionals detect faults on Zodiac® electric robots.

Depending on your needs (and the appliance to be inspected), you may carry out 2 types of test:
- Quick Test: 

This is a "simplified" test using the Diag Box tool only (may be carried out in the field, for example).

This mode lets you launch automatic verification cycles and view a certain number of steps and any error codes directly 

on the Diag Box;

During the test, do not touch the robot or press the keys on the robot control unit.

- Full Test: 

This "enhanced" mode lets you view or export more detailed information (number of hours' operation, error 

history, etc.).

To use this mode, simply connect the Diag Box to a computer (via the USB cable included) and use an additional free 

software package (Full Test Software, which may be downloaded from the Zodiac website: $.8).

3. Electrical connection

- To connect the adaptor, follow the configuration below: End with coloured ring on the Diag Box side

.

Connect the USB cable from the Diag Box to the computer to use Full Test mode only, otherwise the Quick 

Test functions will no longer be accessible.

 - Mains connection. 

dia6

 message displayed.

1

Computer connection

 (for Full Test mode only), §.8

3

- Robot

- Control box

- Motor unit

2

3.1 Specific connection for Lazernaut, Cybernaut™ NT (>2010)

Image 1. Open the robot's control box

Image 2. Connect the yellow adaptor between the Diag 

Box and the robot's control box

Содержание Diag box

Страница 1: ......

Страница 2: ...operations check that The voltage indicated on the appliance s information plate corresponds to the mains voltage The power grid is adapted to the power requirements of the appliance and is grounded T...

Страница 3: ...ing with the device it is vital that you read this installation and user manual as well as the warnings and warranty booklet delivered with the device Failure to do so may result in material damage or...

Страница 4: ...test do not touch the robot or press the keys on the robot control unit Full Test This enhanced mode lets you view or export more detailed information number of hours operation error history etc To u...

Страница 5: ...ortex 1 Test Robot TEST Connect the Diag Box Connect the robot to the Diag Box using the red adaptor Press Cleaner then Start Stop End Press Start Stop or OK or Cancel Vortex 1 robot test Dia6 Test En...

Страница 6: ...n connector Press Cleaner then Start Stop Change the motor unit Fail Com Fail Com TEST OK TEST OK Fail At Refer to the fault description at the top of the flow chart Dia6 Fail Com Refer to the fault d...

Страница 7: ...l box test Press Ebox then Start Stop Fail aT Press Ebox then Start Stop Disconnect reconnect the Diag Box Fail aT Change the Diag Box TEST OK Dia6 OK OK TEST TEST Fail OK Fail Com Change the control...

Страница 8: ...nect the motor unit Diag Box assembly Press Cleaner then Start Stop Change the motor unit Fail Com OK TEST OK OK Rotation right test Rotation left test Fail trac Change the motor unit Fail pump Change...

Страница 9: ...ption at the top of the flow chart Dia6 Pump motor stop Press Cleaner then Start Stop Connect the robot control box to the robot Connect the Diag Box Connect the robot control box to the Diag Box usin...

Страница 10: ...8 Full Test enhanced mode with Full Test Software application 8 1 Downloading Full Test Software Before you use the tool for the first time download the Full test Software application from www zodiac...

Страница 11: ...ctromagnetic compatibility directive 2004 108 EC EN 55014 1 2000 A1 2001 A2 2002 EN 55014 2 1997 A1 2002 EN 60335 1 2002 A1 2004 A2 2006 A11 2004 A12 2006 EN 60335 2 41 2003 A1 2004 Relative to which...

Страница 12: ......

Отзывы: