ZMC460N Motion Controller User Manual V1.5
communication rate, max 100m is recommended.
→
Wiring Reference
Connect 485A and 485B of RS485 to 485A and 485B of the controller correspondingly,
and connect the common terminal EGND of both parties of RS485 communication
together.
Connect the CANL and CANH of the standard CAN module to the CANL and CANH of
the other side correspondingly. And public ends of the CAN bus communication both
parties are connected together. In CAN bus left and right sides, connect a 120
Ω
resistor
respectively (please see below graphic).
→
Wiring Notes:
⚫
As above, the daisy chain topology is used for wiring, and the star topology cannot
be used. When the use environment is ideal and there are few nodes, the branch