ZMC420SCAN Motion Controller Hardware Manual V1.5
ON, PWM will output actually, in this way, laser energy can be controlled.
➢
ZMC420SCAN OUT0-7 have the function of precision output, and each precision output function
is independent, and the same one MOVEOP_DELAY and AXIS_ZSET can be used to set whether
each MOVE_OP uses precision output and precision output delay function or not, then achieve
laser PSO control.
➢
Single-ended pulse axis 6-11 need to be configured as local axes compulsively through
AXIS_ADDRESS, then they can be used, and they are general outputs when ATYPE=0.
3.5.1.
Digital Output Specification & Wiring
→
Specification
Item
High Speed Output (OUT0-11)
Low Speed
Output mode
NPN leakage type, it is 0V when outputs
Frequency
<
400kHz
<
8kHz
Voltage level
DC24V
DC24V
Max output current
+300mA
+300mA
Max leakage
current when off
25μA
25μA
Respond time to
conduct
1μs
(resistive load typical value)
12μs
Respond time to
close
3μs
80μs
Overcurrent
protection
Support
Support
Isolation method
optoelectronic isolation
Note:
The times in the form are typical based on the resistive load, and may change
when the load circuit changes.
Due to the leak-type output, the shutdown of the output will be obviously
affected by the external load circuit, and the output frequency should not be set
too high in the application.
→
Wiring Reference