background image

                                                 

ZMC408SCAN Hardware Manual Version1.2 

 

22 

 

Guide Control (OUT32) 

Red light control output pin, 24V is valid 

ACON (OUT33) 

Reserve output pin, 24V is valid 

LaserRequest (OUT28) 

Laser requires output, 24V is valid 

Program start (OUT29) 

Program start to output, 24V is valid 

ERST (OUT30) 

Laser reset output, 24V is valid 

10 

LASER ON (OUT31) 

Laser enable output, 24V is valid 

11 

PWM/NC (OUT9) 

Reserve PWM signal, 24V electric level 

12 

Modulation- 

Modulate signal - 

15 

NC 

NC 

16 

LASER_DA 

Analog output, 0-10V, 16 bits resolution 

17 

Error (IN44) 

Laser alarm input, 24V is valid 

18 

Emission EN (IN45) 

Laser emission input, 24V is valid 

19 

Pow Active (IN49) 

Laser main power has been opened, 24V 

is valid 

20 

Power ON (IN48) 

Laser system input when in power on, 

24V is valid 

21 

Laser standby (IN47) 

Laser has been in standby status to input, 

24V is valid 

22 

Ready (IN46) 

Laser is read to input, 24V is valid 

23, 25 

EGND 

Reference grounds of each digital input 

and output 

24 

Mod (OUT8) 

Modulate , 24V electric level 

Input and output signals in above table support customization of other signals except PWM 

and Modulation. 

Содержание ZMC408SCAN

Страница 1: ...ZMC408SCAN Hardware Manual Version 1 2...

Страница 2: ...troduction and routines of each instruction please refer to ZBASIC software manual Information contained in this manual is only for reference Due to improvements in design and functions and other aspe...

Страница 3: ...inition 10 2 2 4 2 Digital output specification 12 2 2 4 3 Digital Output Wiring Example 13 2 2 5 AD DA analog terminal 13 2 2 6 Axis Interface 14 2 2 6 1 Terminal Definition 14 2 2 6 2 Axis wiring ex...

Страница 4: ...are supported ZMC408SCAN series controller supports EtherCAT bus connection the fastest refresh cycle is 500 s and supports linear interpolation of up to 16 axes interpolation of circular spherical el...

Страница 5: ...t needs a dynamic library when the procedure is running zmotion dll 1 3Features Motion control of up to 16 axes EtherCAT encoder axis virtual axis Encoder position measurement is supported and can be...

Страница 6: ...trol interface which supports IPG YLR YLS and other laser power supplies 1 interface is configured to expand IO which can expand externally SPI FIBER and other laser power control interfaces Linear in...

Страница 7: ...enable on position clear error etc Max extended IO Up to 4096 inputs and 4096 outputs PWM 8 general digital outputs OUT0 OUT7 2 specialized laser interface OUT8 and OUT9 Internal AD DA 2 general ADs...

Страница 8: ...2 5 Size 235mm 149mm 50mm Single ended pulse axes need to be configured as the local axis method compulsively through AXIS_ADDRESS Any axis can be mapped to the pulse axis which needs to be configure...

Страница 9: ...ZMC408SCAN Hardware Manual Version1 2 6 2 2 ZMC408SCAN Wiring Reference...

Страница 10: ...between CANL and CANH of the last IO expansion module to promote communication signal quality and increase stability 2 2 2 RS232 RS485 Communication Interface PIN Name Description 1 6 8 NC Reserved 2...

Страница 11: ...t 2 5 IN3 High speed input 3 4 IN4 High speed input 4 3 IN5 High speed input 5 2 IN6 High speed input 6 1 IN7 High speed input 7 PIN Name Description 8 IN8 High speed input 8 7 IN9 High speed input 9...

Страница 12: ...Specification Channel number 10 IN0 IN9 Input method NPN type Input voltage level DC24V Input current typical value 6 8mA Input turn on current 15V Input the minimal current 2 3mA Input impedance 3 3K...

Страница 13: ...5KhZ 2 2 3 3 Digital input wiring example 2 2 4 OUT Digital output 2 2 4 1 Terminal definition PIN Signal Description 1 E24V Output freewheeling protection port it is connected to load power 2 E5V 5V...

Страница 14: ...UT16 Output 16 2 OUT17 Output 17 3 OUT18 Output 18 4 OUT19 Output 19 OUT0 7 are high speed output they support high speed comparison and PWM function E5V power output is used for PWM or common anode u...

Страница 15: ...hotocoupler isolation Overcurrent protection Support motion current is 600mA Output frequency 400KhZ General digital output specification Item Specification Channel number 12 OUT10 OUT19 34 35 Output...

Страница 16: ...8kHz for general output If higher speed is required please contact us to adjust parameters or to customize the hardware 2 2 4 3 Digital Output Wiring Example 2 2 5 AD DA analog terminal PIN Signal Des...

Страница 17: ...on 1 EGND External power ground for servo IO 2 IN24 29 ALM General input recommended as drive alarm 3 OUT12 17 ENABLE General output recommended as drive enable 4 EA Encoder Input 5 EB Encoder Input 6...

Страница 18: ...gital ground 22 DIR Servo Step direction output 23 PUL Servo Step pulse output 24 GND Digital ground 25 Reserved Reserved 26 Reserved Reserved Alarm input position on signal axis enable and error clea...

Страница 19: ...ZMC408SCAN Hardware Manual Version1 2 16 2 2 6 2 Axis wiring example 2 2 6 2 1 Wiring Reference for Low speed Differential Pulse Differential Connection Single ended Connection...

Страница 20: ...al Version1 2 17 Low speed differential pulse wiring reference between ZMC408SCAN and Panasonic servo A5 If connects to high speed differential pulse or encoder axis interface GND must be connected to...

Страница 21: ...ntial Pulse Low speed differential pulse port is used preferentially when speed requirements are met And please connect controller internal digital ground to drive high speed pulse reference ground wh...

Страница 22: ...l Version1 2 19 High speed differential pulse wiring reference between ZMC408SCAN and Panasonic servo A5 If connects to high speed differential pulse or encoder axis interface GND must be connected to...

Страница 23: ...er Axis Interface PIN Signals Description 1 Clk Clock signal 14 Clk Clock signal 2 SYNC Synchronization signal 15 SYNC Synchronization signal 3 X Galvanometer X channel signal 16 X Galvanometer X chan...

Страница 24: ...7 Z RTURN Galvanometer Z channel feedback signal 20 Z RTURN Galvanometer Z channel feedback signal 8 X RTURN Galvanometer X channel feedback signal 21 X RTURN Galvanometer X channel feedback signal 9...

Страница 25: ...al 15 NC NC 16 LASER_DA Analog output 0 10V 16 bits resolution 17 Error IN44 Laser alarm input 24V is valid 18 Emission EN IN45 Laser emission input 24V is valid 19 Pow Active IN49 Laser main power ha...

Страница 26: ...phase signal IN32 3 HB Encoder B phase signal IN33 4 HEMGN Emergency stop signal IN43 5 NC 6 HX1 Select X1 velocity IN34 7 HX10 Select X10 velocity IN34 8 HX100 Select X100 velocity IN34 9 HSU Select...

Страница 27: ...ZMC408SCAN Hardware Manual Version1 2 24 2 2 9 2 Wiring example Handwheel wring circuit handwheel input signal supports 5V 24V electric level input signal and low electric level is valid...

Страница 28: ...0 Expand IO0 67 53 3 EXIO_1 Expand IO1 64 50 4 EXIO_2 Expand IO2 59 9 5 EXIO_3 Expand IO3 57 43 6 GND Internal digital ground output 7 EXIO_4 Expand IO4 65 51 8 EXIO_5 Expand IO5 51 37 9 EXIO_6 Expand...

Страница 29: ...19 69 55 24 GND Internal digital ground output 25 5V 5V power output EXIO_0 EXIO_19 all can be configured as input or output port and relative number are in right Signals in this interface can t conne...

Страница 30: ...application ZIO power channels on expansion modules can share the same power supply When ZMC408SCAN controller and ZIO module uses different powers the EGND of controller must be connected to the GND...

Страница 31: ...ing resistance used in the photoelectric isolation circuit of pulse and direction signal output is too large and the working current is too small Motor is under control but it may oscillate or overtur...

Страница 32: ...mputer is same as that of controller Serial port on controller cannot be connected Check whether the serial port parameters have been modified by the running program you can check all the current seri...

Страница 33: ...2 30 Chapter V Hardware Installation 5 1 ZMC408SCAN Installation Size Units mm Mounting hole diameter 4 5mm 5 2 Comprehensive Wiring Reference Please refer to ZIO Expansion card hardware manuals and...

Страница 34: ...Electrical technical parameters 6 1 1 Power demand Item Parameter Power voltage Recommended DC24V max is 18 36V Open current 0 5A DC24V Work current 0 4A DC24V 6 1 2 Work Environment Item Parameter Wo...

Отзывы: