ZMC408SCAN Hardware Manual Version1.2
22
5
Guide Control (OUT32)
Red light control output pin, 24V is valid
6
ACON (OUT33)
Reserve output pin, 24V is valid
7
LaserRequest (OUT28)
Laser requires output, 24V is valid
8
Program start (OUT29)
Program start to output, 24V is valid
9
ERST (OUT30)
Laser reset output, 24V is valid
10
LASER ON (OUT31)
Laser enable output, 24V is valid
11
PWM/NC (OUT9)
Reserve PWM signal, 24V electric level
12
Modulation-
Modulate signal -
15
NC
NC
16
LASER_DA
Analog output, 0-10V, 16 bits resolution
17
Error (IN44)
Laser alarm input, 24V is valid
18
Emission EN (IN45)
Laser emission input, 24V is valid
19
Pow Active (IN49)
Laser main power has been opened, 24V
is valid
20
Power ON (IN48)
Laser system input when in power on,
24V is valid
21
Laser standby (IN47)
Laser has been in standby status to input,
24V is valid
22
Ready (IN46)
Laser is read to input, 24V is valid
23, 25
EGND
Reference grounds of each digital input
and output
24
Mod (OUT8)
Modulate , 24V electric level
Input and output signals in above table support customization of other signals except PWM