X Series User’s Manual
Chapter 2 Installation & Operation
Advanced Functions
Media Sensor Calibration
It is necessary to accomplish Media Sensor Calibration after a new roll of media has been loaded.
1. Press and hold the FEED key for about 4 seconds.
2. The printer will feed approximately 200mm of media;
3. The three indicators stop flashing and remain lit. The printer is back to a normal state.
Self Test
1. Press and hold the PAUSE key for about 4 seconds;
2. The printer will print out a configuration report and the three indicators will stop blinking and remain lit.
The printer is back to a
normal state.
3. The following information will be printed on the self-test report:
- Printer’s model and part number.
- Firmware version
- Hardware configuration and status
- DIP switch settings
- Label parameters
- Font list
Reset – Reset the Printer to the Factory Default Settings
Following the steps listed below allows you to reset the printer to the factory default settings.
1. Press and hold the CANCEL key for 4 seconds, the three lamps will flash simultaneously (the printer
will return to normal state automatically if no operations are performed within 4 seconds);
2. Release and press the CANCEL key again;
3. The three indicators stop flashing and remain lit. The printer is now in its normal state.
The following parameters have automatically been reset:
- Label
- Print darkness
- Speed
- Others
Note
:
The printed label count and printed length may not be reset.
Содержание X1
Страница 1: ...User s Manual ZMIN TECHNOLOGIES 2015 4 8 Version 1 5 Part Number 8010001002 X Series Label Printer...
Страница 18: ...17 8010001002 X Series User s Manual Chapter 2 Installation Operation Figure 5 3...
Страница 24: ...23 8010001002 X Series User s Manual Chapter 2 Installation Operation Figure 6 2...
Страница 26: ...25 8010001002 X Series User s Manual Chapter 2 Installation Operation Figure 6 4 Click...
Страница 43: ...SHENZHEN ZMIN TECHNOLOGIES CO LTD 8010001002...