![ZMD TSic LABkit Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/zmd/tsic-labkit/tsic-labkit_user-manual-and-technical-description_3906478012.webp)
TSic LABkit™ User Manual and Technical Description
TSic
TM
LABkit, Rev.2.4, Oct. 18, 2005
Page 12 of 18
© ZMD AG & IST AG, 2005
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior
written consent of the copyright owner.
Figure 6.1
– Sensor Adaptor Overview
6.2
Requirements for Customized Cables for Other TSic
TM
Types
•
Temperature-proof, 3-pole cable up to 90 ft / 30m
•
Blocking capacitor: 100nF connected close to the sensor between VDD and GND
•
3-pole connector: Schukat Electronics, part no. NSG25-3, crimp contact NSK25-0
7 Electromagnetic Compatibility (EMC- Standard 89/336/EU)
The TSic LABKIT™ USB Adapter meets the electromagnetic compatibility requirements of the following
standards:
EN 61000-6-3 (2001) Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission
standard for residential, commercial and light-industrial environments
EN 61000-6-1 (2001) Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for
residential, commercial and light-industrial environments
For more detailed information, please contact the manufacturer, HYGROSENS INSTRUMENTS GmbH,
Germany, www.hygrosens.com.