background image

                 

ZLIM42    Integrated Open Loop Step Motor Manual Version 1.01

       

                 

ZLIM42    Integrated Open Loop Step Motor Manual Version 1.01 

11  

Shenzhen ZhongLing Technology Co.,Ltd.    TEL: +86-0755-29799302  FAX

+86-0755-2912 4283 WEB

www.zlingkj.com

                Shenzhen ZhongLing Technology Co.,Ltd.    TEL: +86-0755-29799302  FAX

+86-0755-2912 4283 WEB

www.zlingkj.com

   

12 

3.1.3 Control signal port 

Port 

PIN 

Mark 

Name 

Function 

 
 

1

2

3

4

5

6

7

8

 

PUL+ 

 

Pulse input 

The default input voltage is 5V. For other 
voltages, current limiting resistors must 
be added, for example: 12V, external 1K 
1 / 2W resistor, 24V, external 2K 1 / 2W 
resistor. 

PUL- 

DIR+ 

 

Direction 

input 

The default input voltage is 5V. For other 
voltages, current limiting resistors must 
be added, for example: 12V, external 1K 
1 / 2W resistor, 24V, external 2K 1 / 2W 
resistor. 

DIR - 

ENA+ 

 

Enable 

input 

The default input voltage is 5V. For other 
voltages, current limiting resistors must 
be added, for example: 12V, external 1K 
1 / 2W resistor, 24V, external 2K 1 / 2W 
resistor. 

ENA- 

ALM+ 

Alarm 

input 

Optically isolated OC output 

ALM- 

3.2

 

Control Signal Wiring 

If input control signal is differential, its control signal interface wiring diagram is shown 
in Figure 2. 

 

Fig.2 Control signal interface wiring diagram 

 

If input control signal single-ended, its control signal interface wiring diagram is shown 
in Figure 3:   

 

Fig.3 Input interface circuit

 

 

Note: The default input voltage of the control signal is 5V. For other voltages, current 
limiting resistors must be added. For example: 12V, external 1K 1 / 2W resistor;  24V, 
external 2K 1 / 2W resistor. 
 

Control signal timing diagram 

In order to avoid some malfunctions and deviations, PUL, DIR and ENA should meet 
certain requirements, as shown in the figure below: 

Fig.4 Control signal timing diagram

 

Note: 
1) t1: ENA (enable signal) should be confirmed to be high at least 100ms ahead of DIR, 
to ensure that the brake is open, and the motor enters running state, to avoid 

Содержание ZLIM42

Страница 1: ... Tiezai Rd Xixiang St Bao an Dist Shenzhen China Postcode 518102 Tel 86 0755 2979 9302 Fax 86 0755 2912 4283 Email sales zlingkj com Web www zlingkj com ZLIM42 Integrated Open Loop Step Motor Manual PULSE CONTROL Please read t he manual in det ail bef ore use to avoid damage to t he mot or ...

Страница 2: ...ENVIRONMENTAL INDEX 8 2 1 ELECTRICAL INDEX 8 2 2 ENVIROMENTAL INDEX 8 2 3 INSTALLATION DIAGRAM 9 2 4 INSTALLATION 9 3 DRIVER INTERFACE AND WIRING 10 3 1 INTERFACE DEFINITION 10 3 2 CONTROL SIGNAL WIRING 11 3 3 OUTPUT SIGNAL WIRING 13 3 4 STATUS INDICATOR LED 13 4 DIP SWITCH SETTING 14 4 1 STEP RESOLUTION SETTING 14 4 2 MOTOR ROTATION DIRECTION SETTING 15 RELEASE NOTES Version Update time Update Co...

Страница 3: ... motor which is damaged or with missing parts Installation Installed on a non flammable metal frame prevent the intrusion of dust corrosive gases conductive objects liquids and flammable materials and maintain good heat dissipation conditions During installation be sure to tighten the mounting screws of the integrated step servo motor It should be protected from vibration and shock Wiring Please p...

Страница 4: ...ce and Inspection Do not touch the integrated step servo motor terminals directly and some have high voltage very dangerous Before powering up be sure to install the cover when removing the cover be sure to cut off the power supply first Before wiring please confirm whether the input power is off After cutting off the main circuit input power and confirming the integrated step servo motor indicato...

Страница 5: ...nit 1 Input voltage 12V 26VDC 3 Isolated differential signal input 5VDC 1 isolated output port alarm output OC 3 DIP switch selection 8 segment step resolution default step resolution 4 512 can be customized according to customer Automatic flow reduction function 50 With over voltage over current over differential protection functions 1 3 Application Suitable for all kinds of small automation equi...

Страница 6: ...e four corners The integrated step servo motor will generate heat If continuous operation is under high input voltage and high power conditions the effective heat dissipation area or forced cooling should be expanded Do not use in places where air is not circulating or where the ambient temperature exceeds 60 do not install it in a place that is wet or has metal shavings 3 DRIVER INTERFACE AND WIR...

Страница 7: ...tages current limiting resistors must be added for example 12V external 1K 1 2W resistor 24V external 2K 1 2W resistor 6 ENA 7 ALM Alarm input Optically isolated OC output 8 ALM 3 2 Control Signal Wiring If input control signal is differential its control signal interface wiring diagram is shown in Figure 2 Fig 2 Control signal interface wiring diagram If input control signal single ended its cont...

Страница 8: ...ult can be cleared when the user needs to power off and restart the power The status indicator LED represents different operation and fault information as shown in the following table Status Condition Status indicator LED description over voltage Power supply voltage exceeds maximum rated voltage 1 red over current The phase current through the motor exceeds the rated current or the phase to phase...

Страница 9: ...AX 86 0755 2912 4283 WEB www zlingkj com Shenzhen ZhongLing Technology Co Ltd TEL 86 0755 29799302 FAX 86 0755 2912 4283 WEB www zlingkj com 16 ON OFF ON OFF 4000 OFF OFF ON OFF 5000 ON ON OFF OFF 8000 OFF ON OFF OFF 10000 ON OFF OFF OFF 20000 OFF OFF OFF OFF 25000 4 2 Motor Rotation Direction Setting SW1 off the motor rotates counterclockwise CCW SW1 on clockwise rotation CW ...

Отзывы: