PREFACE 

Thanks for choosing ZLIM42, the integrated open loop stepper motor.

 

This manual describes the installation, debugging, maintenance, operation and 
other aspects of the integrated open loop stepper motor ZLIM42. Please read this 
manual in detail before use, and be familiar with the safety precautions.

 

This manual may be revised timely when product is improved, specification  and 
version are changed or for some other reasons, which will not be notified 
particularly.   
Any questions when using our products, please read the relevant manual or call our 
technical service department, we will meet your requirements in the shortest 
possible time. 

 

Marks and warning signal: 

   

Danger: Indicates that this operation error may  endanger 

personal safety!

 

 

 

   

Attention: Indicates that this operation error may result in 

equipment damage!

 

 

SAFETY PRECAUTIONS 

Open Box and Check 

Do not install integrated step-servo motor  which is damaged or with 

missing parts. 

Installation 

  Installed on a non-flammable metal frame, prevent the intrusion of 

dust, corrosive gases, conductive objects, liquids and flammable materials, and 
maintain good heat dissipation conditions. 

 

  During installation, be sure to tighten the mounting screws of the 

integrated step-servo motor. It should be protected from vibration and shock.

 

Wiring 

  Please perform the wiring work by professional electrical engineer;

 

  Before wiring, please confirm that the input power is off. Wiring and 

inspection must be performed after the power is turned off and the integrated 
step-servo motor indicator is off to prevent electric shock

  When plugging and unplugging the integrated step-servo motor 

terminals, make sure that its indicator is off before proceeding;

 

  Please set the emergent stop circuit outside the controller;

 

  Please tighten the output terminal with a suitable torque.

 

Electrify 

  Please confirm whether the main circuit input power is consistent with 

the rated working voltage of the integrated step-servo motor; 

  Do not test the integrated step-servo  motor for high voltage and 

insulation resistance at will;

 

 

Do not connect the electromagnetic contactor or electromagnetic 

switch to the output circuit.

 

Operation 

  Do not directly touch the output terminals after the integrated 

step-servo motor is powered on;

 

  When the system is running, the integrated step-servo  motor may 

Содержание ZLIM42

Страница 1: ... Tiezai Rd Xixiang St Bao an Dist Shenzhen China Postcode 518102 Tel 86 0755 2979 9302 Fax 86 0755 2912 4283 Email sales zlingkj com Web www zlingkj com ZLIM42 Integrated Open Loop Step Motor Manual PULSE CONTROL Please read t he manual in det ail bef ore use to avoid damage to t he mot or ...

Страница 2: ...ENVIRONMENTAL INDEX 8 2 1 ELECTRICAL INDEX 8 2 2 ENVIROMENTAL INDEX 8 2 3 INSTALLATION DIAGRAM 9 2 4 INSTALLATION 9 3 DRIVER INTERFACE AND WIRING 10 3 1 INTERFACE DEFINITION 10 3 2 CONTROL SIGNAL WIRING 11 3 3 OUTPUT SIGNAL WIRING 13 3 4 STATUS INDICATOR LED 13 4 DIP SWITCH SETTING 14 4 1 STEP RESOLUTION SETTING 14 4 2 MOTOR ROTATION DIRECTION SETTING 15 RELEASE NOTES Version Update time Update Co...

Страница 3: ... motor which is damaged or with missing parts Installation Installed on a non flammable metal frame prevent the intrusion of dust corrosive gases conductive objects liquids and flammable materials and maintain good heat dissipation conditions During installation be sure to tighten the mounting screws of the integrated step servo motor It should be protected from vibration and shock Wiring Please p...

Страница 4: ...ce and Inspection Do not touch the integrated step servo motor terminals directly and some have high voltage very dangerous Before powering up be sure to install the cover when removing the cover be sure to cut off the power supply first Before wiring please confirm whether the input power is off After cutting off the main circuit input power and confirming the integrated step servo motor indicato...

Страница 5: ...nit 1 Input voltage 12V 26VDC 3 Isolated differential signal input 5VDC 1 isolated output port alarm output OC 3 DIP switch selection 8 segment step resolution default step resolution 4 512 can be customized according to customer Automatic flow reduction function 50 With over voltage over current over differential protection functions 1 3 Application Suitable for all kinds of small automation equi...

Страница 6: ...e four corners The integrated step servo motor will generate heat If continuous operation is under high input voltage and high power conditions the effective heat dissipation area or forced cooling should be expanded Do not use in places where air is not circulating or where the ambient temperature exceeds 60 do not install it in a place that is wet or has metal shavings 3 DRIVER INTERFACE AND WIR...

Страница 7: ...tages current limiting resistors must be added for example 12V external 1K 1 2W resistor 24V external 2K 1 2W resistor 6 ENA 7 ALM Alarm input Optically isolated OC output 8 ALM 3 2 Control Signal Wiring If input control signal is differential its control signal interface wiring diagram is shown in Figure 2 Fig 2 Control signal interface wiring diagram If input control signal single ended its cont...

Страница 8: ...ult can be cleared when the user needs to power off and restart the power The status indicator LED represents different operation and fault information as shown in the following table Status Condition Status indicator LED description over voltage Power supply voltage exceeds maximum rated voltage 1 red over current The phase current through the motor exceeds the rated current or the phase to phase...

Страница 9: ...AX 86 0755 2912 4283 WEB www zlingkj com Shenzhen ZhongLing Technology Co Ltd TEL 86 0755 29799302 FAX 86 0755 2912 4283 WEB www zlingkj com 16 ON OFF ON OFF 4000 OFF OFF ON OFF 5000 ON ON OFF OFF 8000 OFF ON OFF OFF 10000 ON OFF OFF OFF 20000 OFF OFF OFF OFF 25000 4 2 Motor Rotation Direction Setting SW1 off the motor rotates counterclockwise CCW SW1 on clockwise rotation CW ...

Отзывы: