ZLIM42 Integrated Open Loop Step Motor Manual Version 1.01
ZLIM42 Integrated Open Loop Step Motor Manual Version 1.01
9
Shenzhen ZhongLing Technology Co.,Ltd. TEL: +86-0755-29799302 FAX
:
+86-0755-2912 4283 WEB:
Shenzhen ZhongLing Technology Co.,Ltd. TEL: +86-0755-29799302 FAX
:
+86-0755-2912 4283 WEB:
10
2.3
Installation Diagram
Fig.1 Installation dimension diagram (Unit: mm)
There are 2 options for L:70mm, 82mm. 2 options for
∅
D: 5mm, 8mm.
2.4
Installation
User could mount with the mounting holes on the front of the integrated step-servo
motor. Use M3 screw to install through the holes in the four corners. The integrated
step-servo motor will generate heat. If continuous operation is under high input voltage
and high power conditions, the effective heat dissipation area or forced cooling should
be expanded. Do not use in places where air is not circulating or where the ambient
temperature exceeds 60
℃
; do not install it in a place that is wet or has metal shavings.
3.
DRIVER INTERFACE AND WIRING
3.1 Interface Definition
3.1.1 Power input port
Port
Pin
Mark
Name
Function
6
5
4
3
2
1
6
DC
Power
interface
Power supply 12-24V
5
GND
4
NC
Floating
interface
Normal: NC
3
NC
2
NC
1
NC
3.1.2 DIP switch
Port
Pin
Mark
Name
Function
1 2 3 4 5
1
SW1
DIP switch
Motor direction selection
2
SW2
Step resolution setting;
Default value 1-128;
Could be customized according to
customer’s demand.
3
SW3
4
SW4
5
SW5